Keithley - 6517 - Analog multimeter
Manufacturer:
Equipment:
6517
Date:
1996
Category:
Group:
Sub Group:
Information
Some important Model
6517 features include:
• Full range of functions — Exceptional sensitivity and
accuracy for voltage, current, charge, and V/I resistance
and resistivity (surface and volume) measurements. With the
Models 6517-RH and 6517-TP, relative humidity and external
temperature can be measured,
• Voltage source — The internal 1000V V-Source can be
configured with the ammeter to make V/I
resistance/resistivity measurements* and to force voltage,
measure current.
• Two-line display — Readings and front panel messages are
provided on the top line (primary) 20-character, and bottom
line (secondary) 32-character alphanumeric display. The
multiple display provides supplemental infor-
mation about the reading, such as min/max readings, bar
graphs for the reading, and time and date.
* Reading and setup storage — Readings and setup data can be
stored and recalled from memory. Over 15.000 readings can be
stored in the buffer, and up to 10 instrument setups can be
stored in memory.
* Test sequences — Built-in tests for the following
applications: device characterization, resistivity, surface
insulation resistance, and voltage sweeps.
* GPIB interface — Accommodates two separate languages for
IEEE-488 operation. The SCPI language conforms to the
IEEE-488.2 and SCPI standards. The 617 emulation mode (DDC
language) allows the instrument to be controlled using
device-dependent command programming.
a RS-232 interface — The instrument can instead be
controlled over this serial interface using SCPI commands.
* Talk-only mode — From the front panel, you can set the
instrument to send readings to a printer. Talk-only is
available over both the GPIB and RS-232 interfaces.
» Scanning — The Model
6517 has an option slot that will
accommodate an optional scanner card (Models 6521 and 6522).
The instrument can also be configured to operate with an
external switching system (i.e.. Model
7001 or 7002) to scan
external channels.
* Trigger link — This is a new trigger concept that provides
more versatile and precise external triggering. It is in
addition to the standard Trigger In/Meter Complete Out BNC
external triggering techniques.
* Digital calibration — The instrument may he digitally
calibrated from either the front panel, or over the RS-232
interface or GPIB bus (SCPI language).
Service manual
Manual type:
Service manual
Pages:
119
Size:
2.7 MB
Language:
english
Revision:
Second Printing
Manual-ID:
6517A-902-01
Date:
Quality:
Scanned document, all readable.
Upload date:
March 1, 2014
MD5:
72eb0b9e-e5c5-a141-5328-6536a1bd19cb
Downloads:
1327
Service and user manual
Manual type:
Service and user manual
Pages:
340
Size:
2.9 MB
Language:
english
Revision:
C
Manual-ID:
6517A-900-01
Date:
Quality:
Electronic document, no scan, very well readable.
Upload date:
March 2, 2014
MD5:
9af495cb-7732-d396-145e-1c7e82b8aa63
Downloads:
1277
User manual
Manual type:
User manual
Pages:
110
Size:
1.8 MB
Language:
english
Revision:
A
Manual-ID:
6517A-903-01
Date:
Quality:
Electronic document, no scan, very well readable.
Upload date:
March 7, 2014
MD5:
128dde8a-6c63-3553-8ce4-b2782e7a49d3
Downloads:
1197
User manual
Manual type:
User manual
Pages:
334
Size:
13.6 MB
Language:
english
Revision:
D
Manual-ID:
6517-900-01
Date:
July 1995
Quality:
Scanned document, all readable.
Upload date:
Aug. 24, 2018
MD5:
9bc8ff03-1455-5ab0-ac10-e8623f693ef0
Downloads:
523