Electronic Measurements Inc. - TCR 1 Phase - Power supply
Manufacturer:
No picture available!
Maybe you can
upload a pic
for the
Electronic Measurements Inc. TCR 1 Phase ?
If you have any other manuals for the
Electronic Measurements Inc. TCR 1 Phase
you can
upload the files here.
.
Equipment:
TCR 1 Phase
Date:
1984
Category:
Group:
Sub Group:
Information
Constant voltage mode; Variations in output current from 5
to 100% of maximum rating cause output voltage variations of
less than 0.1% of the output voltage setting when output is
50 to 100% of the maximum rating. Below 50% output voltage,
output variation will not exceed 0.05% of maximum output.
Constant current Mode: Variations in- output voltage from 5
to 100% of maximum rating cause output current variations of
less than 0.1% of the output voltage setting when output is
50 to 100% of the maximum rating. Below 50% output current,
output variation will not exceed 0.05% of.maximum output
Ripple: Measured with either positive or negative grounded,
maximum output voltage and full current into a resistive
load.'(See Rating Chart) At 50Hz AC input ripple is 30%
above 60Hz ratings.
Stability: The output voltage or current will remain within
± 0.05% for 8 hours after warm-up, with constant line, load
and temperature.
Transient Response: A 30% step increase inpower demanded by
the load will cause a transient in the regulated output
which will typically recover to within 2% of final value
within 75ms.
Service and user manual
Manual type:
Service and user manual
Pages:
66
Size:
2.6 MB
Language:
english
Revision:
D
Manual-ID:
Date:
January 1984
Quality:
Scanned document, reading partly badly, partly not readable.
Upload date:
Oct. 3, 2016
MD5:
284edf60-4242-91bf-9d2d-99d6842570cf
Downloads:
366