.....obsolete user manuals, a lot of repair manuals, free service manuals, rare schematic diagrams, usefull service instructions, pdf books, how to repair instructions, lost operating manuals, old handbooks, tons of part lists, hidden service bulletins, your instruction books, informative repair tips, complete disassembly routines.....


What are you looking for?


Dranetz Engineering Laboratories Inc. - 305-PA-3009 - Network Analyzer
Manufacturer:
Equipment:
305-PA-3009
Date:
1976
Category:
Group:
Sub Group:

Information

PURPOSE The purpose of this plug-in is to expand the usefulness of Dranetz Series 305 phasemeters by adding the ability to measure the voltage of both inputs in either volts or dB reference 1 Volt = 0 db. The ratio in dB of the "Signal” input with respect to the "Reference" is also measured, 1.3 CHARACTERISTICS The detailed characteristics of the 305~PA~3009 when used in a series 305 phasemeter are specified by Table 1.1 which follows: TABLE 1.1, 305-PA-3009 SPECIFICATIONS INPUT LEVEL RANGE: 10 mV rms to 40 V rms both inputs. INPUT IMPEDANCE: 1 Megohm plus 40 pf both inputs, usable with standard oscilloscope probes. INPUT FREQUENCY RANGE: 2 Hz to 700 kHZ FUNCTIONS: Amplitude of reference input in volts or dR ref 1 volt, Amplitude of signal input in volts or dB ref 1 volt. Phase angle of signal input with respect to reference input, and Ratio of signal input to reference input in dB, The function to be displayed is selected by a switch on the front panel of the plug-in. ANALOG OUTPUTS: Four Outputs are simultaneously available at the rear of the. phasemeter main frame* They are proportional to Reference input level (in either volts or d b) , Signal input level (in either volts or d b ) , Phase Angle of Signal with respect to reference* and ratio of signal to Reference In db. The sensitivity of all db outputs is 10 mv/db, The sensitivity of the phase angle Output is 10 mv / degrees (a positive, output indicates that Signal leads Reference). The voltage amplitude output« have one of 3 sensitivities depending on which voltage range is in use* Sensitivity Is 10 volts/ volt in the mv x 1 range, 1 volt/volt in the mv x 10 range and 0*1 volt/volt in the volts *10 range.

show more

1 Manual

Service and user manual
Manual type:
Service and user manual
Pages:
36
Size:
992.8 KB
Language:
english
Revision:
Manual-ID:
TM-102,848
Date:
September 1976
Quality:
Scanned document, reading partly badly, partly not readable.
Upload date:
Aug. 11, 2017
MD5:
f0e97ca7-5ebd-d086-a907-032f20368e9e
Downloads:
312