The HP Model 5383A is a direct-counting Frequency counter that has a range of 10 Hz to 512 MHz. Nine display digits
provide a resolution of one Hz per second for inputs up to
512 MHz. Front panel controls allow a selection of gate
times, input impedances, and attenuators. A rear panel
connector and associated selector switch allow either an
external time base Oscillator input, or monitoring of the
internal time base Oscillator When the optional temperature
compensated crystal Oscillator (TCXO) is installed, the rear
panel connector serves only as a time base monitor. In
addition, a rear panel power selector switch permits the 5383A Counter to operate with line voltages ranging from 90V
to 252V (line frequency range: 48 to 440 Hz).
1 Handbuch
Reparatur und Bedienungsanleitung
Dokumenttyp:
Reparatur und Bedienungsanleitung
Seitenanzahl:
57
Größe:
3,1 MB
Sprache:
englisch
Revision:
Dokument-ID:
05383-90001
Datum:
März 1975
Qualität:
Gescanntes Dokument, teilweise schwer oder teilweise nicht zu lesen.
Upload Datum:
30. Dezember 2017
MD5:
a4b7cde5-ceed-69bf-12c7-08eb0c4af4a9
Downloads:
613
Downloads letzter Monat:
3
Informationen
I GENERAL INFORMATION
... 1-1
1-1.
Introduction...
1-1
1-3. Instrument Description
... 1-1
1-5 Accessories and Options
... 1-1
1-8. Instrument Identification
...1-1
1-11. Microfiche Number
... 1-2
1-13. Recommended Test Equipment
... 1-2
1-15.
Specifications...
1-2
II INSTALLATION
...2-1
2-1. Introduction
... 2-1
2-3. Unpacking and Inspection
... 2-1
2-5. Storage and Shipment
...2-1
2-8. Line Voltage
Selection...2-1
2-11. Mounting
...2-2
III OPERATION
... 3-1
3-1.
Introduction...3-1
3-3. Controls, Connectors and Indicators
... 3-1
3-5. Measurement Techniques
...3-1
3-7. Ratio Measurements (Standard Counter Only)...3-1
3-10. Operator Checks
...3-3
IV THEORY OF OPERATION
...4-1
4-1. Introduction
...4-1
4-3. Functional Description
...4-1
4-5. Input
Circuits...4-1
4-7. Balanced Input Amplifier 4-2
4-9. TBO and Main Gate Circuits
...4-2
4-11. Scan Timing Circuits
...4-2
4-15. Multiplexed Display Function
...4-4
4-17. Leading Zero Blanking
...4-4
4-19. Unique Integated Circuits
...4-4
V
MAINTENACE...5-1
5-1.
Introduction...5-1
5-3. In-Cabinet Performance Check
... 5-1
5-5. Adjustments
... 5-5
5-7. Balanced Input Amplifier 5-5
5-10. Standard Time Base Oscillator Adjustment
...5-5
5-13. Option 001 Time Base Oscillator Adjustment
... 5-6
5-16. Instrument Access
... 5-8
5-18. Troubleshooting
... 5-9
VI REPLACEABLE PARTS
...6-1
6-1.
Introduction...6-1
6-4. Ordering Information
...6-1
6-6. LED Display Digit Ordering Information
...6-9
VII MANUAL CHANGES
...7-1
7-1.
Introduction...
7-1
7-3. Manual
Changes...7-1
7-5. Newer
Instruments... 7-1
VIII SCHEMATIC
DIAGRAMS...8-1
8-1.
Introduction...8-1