.....obsolete Bedienungsanleitungen, eine Menge Reparaturanleitungen, kostenlose Serviceanleitungen, seltene Schaltpläne, nützliche Serviceanleitungen, pdf-Bücher, Reparaturanleitungen, verlorene Bedienungsanleitungen, alte Handbücher, tonnenweise Teilelisten, versteckte Service Bulletins, Ihre Bedienungsanleitungen, informative Reparaturtipps, komplette Demontageanleitungen.....


Wonach suchen Sie?


Kenwood - CS-1012 - Oszilloskop
Hersteller:
Gerät:
CS-1012
Datum:
1991
Kategorie:
Gruppe:
Untergruppe:

Informationen

Vertical axis has high sensitivity and wide bandwidth and especially covers fully specified frequency response at 2mV/div for all models. CS-1022, 1021 ; Dual Trace 1 mV/div : DC to 10 MHz, -3 dB 2mV/div : DC to 20 MHz, -3 dB CS-1012 ; Dual Trace 1 mV/div : DC to 7 MHz, -3 dB 2mV/div : DC to 10 MHz, -3 dB CS-1020 ; Single Trace 1 mV/div : DC to 10 MHz, -3 dB 2mV/div : DC to 20 MHz, -3 dB CS-1010 ; Single Trace 1 mV/div : DC to 7 MHz, -3 dB 2mV/div : DC to 10 MHz, -3 dB • Vertical sensitivity range is selectable from 1 mV/div to 5V/div with rotary switch continuously. • Time base permits the high sweep speed. CS-1022, 1020; 20nsec/div (x10 MAG) CS-1021, 1012, 1010; 50nsec/div (x10 MAG) • Vertical sensitivity error and sweep rate error are ±3% and accurate measurements are provided. • The 150 mm rectangular CRT with internal graticule provides high brightness and accurate measurements, free of parallax error. CS-1022, 1020; domed mesh type CRT with post deflection acceleration and high brightness phosphors (acceleration voltage; 6 kV). CS-1021, 1012, 1010; high brightness CRT (acceleration voltage; 2 kV). • For convenience in making rise time measurements, the 0%, 10%, 90% and 100% levels are marked on the graticule scale of the CRT. • Trace rotation is electrically adjustable from the front panel. • By SCALE ILLUM control, the waveform is easy observed in the dark and the photograph of the waveform is easy provided. (Except CS-1021) • Selectable AUTO FREE RUN function provides sweep without trigger input signal. • The FRAME-LINE switch provides selection of sync pulse for sweep triggering from small amplitude to large amplitude without adjusting when viewing composite video waveforms. • For CS-1022, 1021 and 1012, vertical mode automatically provides the trigger signal with TRIG SOURCE and V. MODE switches. • X-Y operation is easy provided by one-touche. CS-1022, 1021, 1012; CH1 Y axis, CH2 X axis CS-1020, 1010; VERT INPUT Y axis EXT TRIG INPUT X axis • CS-1022 and 1012 are provided with CH1 OUTPUT terminal to monitor input signal of CH1. • CS-1020 and 1010 are provided with VERT OUTPUT terminal to monitor input signal of VERT INPUT.

mehr

3 Handbücher

Bedienungsanleitung
Dokumenttyp:
Bedienungsanleitung
Seitenanzahl:
31
Größe:
5,9 MB
Sprache:
Englisch
Revision:
Dokument-ID:
B50-7570
Datum:
Dezember 1991
Qualität:
Gescanntes Dokument, alles ist lesbar.
Upload Datum:
17. Mai 2020
MD5:
75cc6fd6-6c3e-d817-f2e8-277923300051
Uploader:
Fabio
Downloads:
1190
Reparaturanleitung
Dokumenttyp:
Reparaturanleitung
Seitenanzahl:
55
Größe:
21,6 MB
Sprache:
Englisch
Revision:
Dokument-ID:
Datum:
Qualität:
Gescanntes Dokument, teilweise schwer oder teilweise nicht zu lesen.
Upload Datum:
28. Dezember 2020
MD5:
2d1f213f-140e-5270-bf13-823c7c21bba5
Uploader:
Guidopianino
Downloads:
685
Reparaturanleitung
Dokumenttyp:
Reparaturanleitung
Seitenanzahl:
87
Größe:
11,9 MB
Sprache:
Englisch
Revision:
Dokument-ID:
Datum:
Qualität:
Gescanntes Dokument, alles ist lesbar.
Upload Datum:
28. Dezember 2020
MD5:
1103c56c-9610-3dcd-cd3c-9fafffac145b
Downloads:
751