.....obsolete Bedienungsanleitungen, eine Menge Reparaturanleitungen, kostenlose Serviceanleitungen, seltene Schaltpläne, nützliche Serviceanleitungen, pdf-Bücher, Reparaturanleitungen, verlorene Bedienungsanleitungen, alte Handbücher, tonnenweise Teilelisten, versteckte Service Bulletins, Ihre Bedienungsanleitungen, informative Reparaturtipps, komplette Demontageanleitungen.....


Wonach suchen Sie?


Metron - QA-IDS - Analyseeinheit
Hersteller:
Gerät:
QA-IDS
Datum:
1998
Kategorie:
Gruppe:
Untergruppe:

Informationen

METRON’s QA-IDS Infusion Pump Tester is a precision instru- ment, designed for use by trained service technicians, for testing all types of infusion pumps according to International Electrotechnical Commission (IEC) Draft Standard 62.D (IEC 601.2.24). Tests include: • volumetric tests • bolus tests • occlusion alarm tests QA-IDS is capable of detecting a minimum volume variation of one microliter in a range of 0.10 milliliter per hour (ml/hr) to 1000.0 ml/hr. Flow measurements are taken every 30 seconds, so that the measurements are independent of the infusion pump’s flow rate. Test results, shown in the QA-IDS's LCD display, can be printed out directly, or transferred to a PC via the PRO-Soft QA-IDS test automation Software PRO-Soft lets you design test protocols, remotely control the QA-IDS and store the test results.

mehr

1 Handbuch

Reparatur und Bedienungsanleitung
Dokumenttyp:
Reparatur und Bedienungsanleitung
Seitenanzahl:
62
Größe:
385,4 KB
Sprache:
englisch
Revision:
Dokument-ID:
15035
Datum:
Januar 1998
Qualität:
Elektronisches Dokument, kein Scan, sehr gut lesbar.
Upload Datum:
16. August 2019
MD5:
4a4545b2-4d60-c7c6-758c-0e61a99848a0
Downloads:
533

Informationen

MANUAL REVISION RECORD...5 1. INTRODUCTION...7 1.1 QA-IDS Features ...7 1.2 Specifications...7 1.3 General Information...8 2. INSTALLATION...9 2.1 Receipt, Inspection and Return...9 2.2 Setup...10 2.3 Power ...10 2.4 PRO-Soft QA-IDS 10 3. OPERATING QA-IDS 13 3.1 Control Switches and Connections...13 3.2 Key Pad Functions...14 3.3 Menu and Function Keys...14 3.4 Display Menus and Messages ...15 3.5 Printing Test Reports...20 3.6 Operator Maintenance...22 4. INFUSION PUMP TESTING...23 4.1 Introduction...23 4.2 Test Preparation...23 4.3 Occlusion Pressure/ Bolus Volume Testing ...25 4.4 Infusion Flow Rate and Volume Testing...26 5. CONTROL AND CALIBRATION...29 5.1 Required Test Equipment...29 5.2 Adjusting the Display Contrast ...29 5.3 Testing Power Supply to IDS...29 5.4 Testing Pressure Gauge Accuracy...30 5.5 Testing Flow Rate Accuracy...30 5.6 Checking the Battery Backup...31 6. COMPONENT FUNCTIONS AND PARTS...33 6.1 Theory of Operation...33 6.2 Power Supply 33 6.3 Printer Output...33 6.4 Serial Port...34 6.5 Microprocessor...34 6.6 Pressure Gauge...34 6.7 Pump...34 6.8 Stepper Motor/Drivers...34 6.9 Control Panel...35 6.10 Component Parts...35 APPENDIX A: DIAGRAMS...39 Processor board Component Location...41 6.10.1 Processor board Schematic Diagram 1 ...42 6.10.2 Processor board Schematic Diagram 2 (Digital Part) ...43 6.10.3 Processor board Schematic Diagram 3 (CPU) ...44 6.10.4 Processor board Schematic Diagram 4 (Memory) ...45 6.10.5 Processor board Schematic Diagram 5 (RS232C and Printer) ...46 6.10.6 Processor board Schematic Diagram 6 (Digital Outputs) ...47 6.10.7 Processor board Schematic Diagram 7 (Digital Inputs) ...48 6.10.8 Processor board Schematic Diagram 8 (A/D) ...49 6.10.9 Processor board Schematic Diagram 9 (Stepper Motor and Drivers) ...50 6.10.10 Processor board Schematic Diagram 10 (Pressure Sensor and Temperature) ...51 6.10.11 Processor board Schematic Diagram 11 (Main Part) ...58 6.10.12 Processor board Schematic Diagram 12 (Keyboard, Pressure Sensor and Pump Index) ...59 APPENDIX B: ERROR REPORT FORM QA-IDS 62 APPENDIX C: SUGGESTION FORM QA-IDS 65

mehr