.....obsolete user manuals, a lot of repair manuals, free service manuals, rare schematic diagrams, usefull service instructions, pdf books, how to repair instructions, lost operating manuals, old handbooks, tons of part lists, hidden service bulletins, your instruction books, informative repair tips, complete disassembly routines.....


What are you looking for?


Fluke - 196B - ScopeMeter
Manufacturer:
Equipment:
196B
Date:
2002
Category:
Group:
Sub Group:

Information

The Fluke I92B 196B C7199B-C ScopeMeter test tools have three input channels that are electrically floating with respect to each other, and with respect to the power adapter input. Channel A and channel B are Oscilloscope channels with a 60/100/200 MHz bandwidth. The Meter/External Trigger channel is a combined DMM and external trigger channel with a limited (10 kHz) bandwidth. The B versions have a black&white LCD, the C versions have a color display.

show more

3 Manuals

Service manual
Manual type:
Service manual
Pages:
206
Size:
9.7 MB
Language:
english
Revision:
Manual-ID:
PN 4822 872 05391
Date:
Quality:
Electronic document, no scan, very well readable.
Upload date:
Nov. 29, 2014
MD5:
951de768-2a2c-1ae7-299f-9ca8aa14f216
Downloads:
4624

Information

1 Safety Instructions ... 1-1 1.1 Introduction... 1-3 1.2 Safety Precautions... 1-3 1.3 Caution and Warning Statements... 1-3 1.4 Symbols... 1-3 1.5 Impaired Safety ... 1-4 1.6 General Safety Information... 1-4 2 Characteristics ... 2-1 2.1 Introduction... 2-3 2.2 Dual Input Oscilloscope 2-3 2.2.1 Isolated Inputs A and B (Vertical)... 2-3 2.2.2 Horizontal ... 2-4 2.2.3 Trigger and Delay ... 2-4 2.2.4 Automatic Connect&View Trigger ... 2-5 2.2.5 Edge Trigger ... 2-5 2.2.6 Isolated External Trigger ... 2-5 2.2.7 Video Trigger... 2-5 2.2.8 Pulse Width Trigger... 2-5 2.2.9 Continuous Auto Set... 2-6 2.2.10 Automatic Capturing Scope Screens ... 2-6 2.3 Automatic Scope Measurements... 2-6 2.3.1 General... 2-6 2.3.2 DC Voltage (VDC)... 2-6 2.3.3 AC Voltage (VAC)... 2-6 2.3.4 AC+DC Voltage (True RMS)... 2-7 2.3.5 Amperes (AMP)... 2-7 2.3.6 Peak... 2-8 2.3.7 Frequency (Hz) ... 2-8 2.3.8 Duty Cycle (DUTY) ... 2-8 2.3.9 Pulse Width (PULSE)... 2-8 2.3.10 Vpwm (C versions only)... 2-8 2.3.11 Power ... 2-9 2.3.12 Phase ... 2-9 2.3.13 Temperature (TEMP) ... 2-9 2.3.14 Decibel (dB)... 2-9 2.4 Meter ... 2-10 2.4.1 Meter Input ... 2-10 2.4.2 Meter Functions... 2-10 2.5 DMM Measurements on Meter Inputs... 2-10 2.5.1 General... 2-10 2.5.2 Ohms (Ω) ... 2-10 2.5.3 Continuity (CONT)... 2-10 2.5.4 Diode... 2-11 2.5.5 Temperature (TEMP)... 2-11 2.5.6 DC Voltage (VDC)... 2-11 2.5.7 AC Voltage (VAC)... 2-11 2.5.8 AC+DC Voltage (True RMS)... 2-11 2.5.9 Amperes (AMP)... 2-12 2.6 Recorder ... 2-12 2.6.1 TrendPlot (Meter or Scope)... 2-12 2.6.2 Scope Record ... 2-12 2.7 Zoom, Replay and Cursors... 2-13 2.7.1 Zoom... 2-13 2.7.2 Replay ... 2-13 2.7.3 Cursor Measurements ... 2-13 2.8 Miscellaneous... 2-13 2.8.1 Display... 2-13 2.8.2 Power ... 2-13 2.8.3 Probe Calibration... 2-14 2.8.4 Memory... 2-14 2.8.5 Mechanical... 2-14 2.8.6 Optical Interface Port... 2-14 2.9 Environmental ... 2-14 2.10 Safety... 2-15 2.11 10:1 Probe VPS200 ... 2-17 2.11.1 Safety ... 2-17 2.11.2 Electrical specifications... 2-17 2.11.3 Environmental... 2-17 2.12 Electromagnetic Immunity... 2-18 3 Circuit Description ... 3-1 3.1 Introduction... 3-3 3.2 Block Diagram ... 3-3 3.3 Start-up Sequence, Operating Modes... 3-7 3.4 Detailed Circuit Descriptions... 3-9 3.4.1 Scope Channel A - Scope Channel B ... 3-9 3.4.2 Meter/Ext Trigger Channel... 3-12 3.4.3 Sampling&Triggering (S-ASIC)... 3-15 3.4.4 S-ASIC supply ... 3-19 3.4.5 ADC’s ... 3-19 3.4.6 Digital Control ... 3-20 3.4.7 LCD Control ... 3-22 3.4.8 Power ... 3-23 3.4.9 Slow ADC, RS232 Serial Interface LCD Backlight... 3-28 4 Performance Verification... 4-1 4.1 Introduction... 4-3 4.2 Equipment Required For Verification ... 4-3 4.3 General Instructions ... 4-3 4.4 Operating Instructions... 4-4 4.4.1 Resetting the test tool ... 4-4 4.4.2 Navigating through menu’s... 4-4 4.4.3 Creating Test Tool Setup1... 4-5 4.5 Display and Backlight Test ... 4-5 4.6 Scope Input A&B Tests ... 4-7 4.6.1 Input A&B Vertical Accuracy Test ... 4-7 4.6.2 Input A&B DC Voltage Accuracy Test... 4-9 4.6.3 Input A&B AC Voltage Accuracy Test (LF)... 4-11 4.6.4 Input A & B AC Coupled Lower Frequency Test ... 4-12 4.6.5 Input A and B Peak Measurements Test... 4-13 4.6.6 Input A&B Frequency Measurement Accuracy Test ... 4-14 4.6.7 Input A&B Phase Measurements Test... 4-15 4.6.8 Time Base Test ... 4-16 4.6.9 Input A Trigger Sensitivity Test ... 4-18 4.6.10 Input A AC Voltage Accuracy (HF) & Bandwidth Test ... 4-19 4.6.11 Input B Trigger Sensitivity Test ... 4-20 4.6.12 Input B AC Voltage Accuracy (HF) & Bandwidth Test ... 4-21 4.6.13 Video test using the Video Pattern Generator 4-22 4.6.14 Video test using SC600 Scope Calibration Option ... 4-25 4.7 External Trigger Level Test ... 4-27 4.8 Meter (DMM) Tests... 4-28 4.8.1 Meter DC Voltage Accuracy Test ... 4-28 4.8.2 Meter AC Voltage Accuracy & Frequency Response Test ... 4-29 4.8.3 Continuity Function Test ... 4-30 4.8.4 Diode Test Function Test ... 4-30 4.8.5 Ohms Measurements Test... 4-30 4.9 Probe Calibration Generator Test ... 4-32 5 Calibration Adjustment ... 5-1 5.1 General ... 5-3 5.1.1 Introduction... 5-3 5.1.2 Calibration number and date... 5-3 5.1.3 General Instructions... 5-3 5.1.4 Equipment Required For Calibration ... 5-4 5.2 Calibration Procedure Steps... 5-4 5.3 Starting the Calibration ... 5-4 5.4 Contrast Calibration Adjustment ... 5-6 5.5 Warming Up & Pre-Calibration ... 5-7 5.6 Final Calibration ... 5-8 5.6.1 Input A LF-HF Gain ... 5-8 5.6.2 Input B LF-HF Gain... 5-9 5.6.3 Input A&B LF-HF Gain... 5-11 5.6.4 Input A&B Position ... 5-12 5.6.5 Input A&B Volt Gain ... 5-13 5.6.6 DMM Volt Gain ... 5-14 5.6.7 Input A& B, and DMM Zero ... 5-15 5.6.8 DMM Ohm Gain... 5-16 5.6.9 Calculate Gain... 5-17 5.7 Save Calibration Data and Exit... 5-17 5.8 Probe Calibration ... 5-19 6 Disassembling the Test Tool ... 6-1 6.1. Introduction... 6-3 6.2. Disassembly & Reassembly Procedures ... 6-3 6.2.1 Required Tools ... 6-3 6.2.2 Removing the Tilt Stand & Hang Strap... 6-3 6.2.3 Replacing the Side-Strap, Changing the Side-Strap Position... 6-3 6.2.4 Opening the Test Tool, Removing the Battery... 6-3 6.2.5 Removing the Main PCA Unit and the Fan... 6-5 6.2.6 Removing the Display Assembly... 6-6 6.2.7 Replacing the LCD Window/Decal ... 6-7 6.2.8 Removing the Keypad and Keypad Foil... 6-7 6.2.9 Disassembling the Main PCA Unit... 6-7 6.2.10 Reassembling the Main PCA Unit... 6-8 6.2.11 Reassembling the Test Tool... 6-9 7 Corrective Maintenance... 7-1 7.1 Introduction... 7-3 7.2 Starting Fault Finding. ... 7-4 7.3 Charger Circuit... 7-5 7.4 Starting with a Dead Test Tool ... 7-7 7.4.1 Test Tool Completely Dead... 7-7 7.4.2 Test Tool Software Does not Run. ... 7-8 7.4.3 Software Runs, Test Tool not Operative ... 7-8 7.5 Miscellaneous Functions... 7-8 7.5.1 Display and Back Light ... 7-8 7.5.2 Fly Back Converter 7-10 7.5.3 Slow ADC, +3V3SADC... 7-11 7.5.4 Keyboard... 7-12 7.5.5 Optical Port (Serial RS232 Interface)... 7-13 7.5.6 Channel A, Channel B Measurements... 7-13 7.5.7 Meter Channel (Ext Trigger Probe Cal) ... 7-15 7.5.8 Input Signal Acquisition ... 7-17 7.5.9 ADC’s ... 7-19 7.5.10 Digital Control & Memory ... 7-20 7.5.11 Buzzer Circuit ... 7-20 7.5.12 RAM Test ... 7-21 7.5.13 Power ON/OFF... 7-22 7.5.14 Battery... 7-22 7.6 Loading Software 7-23 8 List of Replaceable Parts... 8-1 8.1 Introduction... 8-3 8.2 How to Obtain Parts... 8-3 8.3 Service Centers ... 8-3 8.4 Final Assembly Parts... 8-4 8.5 Main PCA Unit Parts ... 8-6 8.6 Main PCA Parts ... 8-8 8.7 Accessories 8-30 9 Circuit Diagrams ... 9-1 9.1 Introduction... 9-3 9.2 Tracing signals in circuit diagrams ... 9-3 9.3 Locating Parts & Test Points ... 9-3 9.4 Diagrams ... 9-6 10 Modifications... 10-1 10.1 General ... 10-3 10.2 Software modifications ... 10-3 10.3 Hardware modifications... 10-3 10.4 Main PCA Unit Versions Software Versions. ... 10-4

show more

Service and user manual
Manual type:
Service and user manual
Pages:
204
Size:
10.0 MB
Language:
english
Revision:
Manual-ID:
4822 872 05391
Date:
Quality:
Scanned document, all readable.
Upload date:
Feb. 8, 2016
MD5:
1a6bb036-69d1-d1db-dc35-1f0c38c4405f
Downloads:
4669

Information

1 Safety Instructions...1-1 1.1 Introduction...1-3 1.2 Safety Precautions...1-3 1.3 Caution and Warning Statements...1-3 1.4 Symbols...1-3 1.5 Impaired Safety...1-4 1.6 General S afety Information...1-4 2 Characteristics...2-1 2.1 Introduction...2-3 2.2 Dual Input Oscilloscope 2-3 2.2.1 Isolated Inputs A and B (Vertical)...2-3 2.2.2 Horizontal...2-4 2.2.3 Trigger and Delay...2-4 2.2.4 Automatic Connect&View Trigger...2-5 2.2.5 Edge Trigger...2-5 2.2.6 Isolated External Trigger...2-5 2.2.7 Video Trigger...2-5 2.2.8 Pulse Width Trigger...2-5 2.2.9 Continuous Auto Set...2-6 2.2.10 Automatic C apturing S cope S creens...2-6 2.3 Automatic Scope Measurements...2-6 2.3.1 General...2-6 2.3.2 DC Voltage (VDC)...2-6 2.3.3 AC Voltage (VAC)...2-6 2.3.4 AC+DC Voltage (True RMS)...2-7 2.3.5 Amperes (AMP)...2-7 2.3.6 Peak...2-8 2.3.7 Frequency (Hz)...2-8 2.3.8 Duty Cycle (DUTY)...2-8 2.3.9 Pulse Width (PULSE)...2-8 2.3.10 Vpwm (C versions only)...2-8 2.3.11 Power...2-9 2.3.12 Phase...2-9 2.3.13 Temperature (TEMP)...2-9 2.3.14 Decibel (dB)...2-9 2.4 Meter...2-10 2.4.1 Meter Input...2-10 2.4.2 Meter Functions...2-10 2.5 DMM Measurements on Meter Inputs...2-10 2.5.1 General...2-10 Chapter Title Page 2.5.2 Ohms (Ω)...2-10 2.5.3 Continuity (CONT)...2-10 2.5.4 Diode...2-11 2.5.5 Temperature (TEMP)...2-11 2.5.6 DC Voltage (VDC)...2-11 2.5.7 AC Voltage (VAC)...2-11 2.5.8 AC+DC Voltage (True RMS)...2-11 2.5.9 Amperes (AMP)...,...2-12 2.6 Recorder...2-12 2.6.1 TrendPlot (Meter or Scope)...2-12 2.6.2 Scope Record...2-12 2.7 Zoom, Replay and Cursors...2-13 2.7.1 Zoom...2-13 2.7.2 Replay...2-13 2.7.3 Cursor Measurements...2-13 2.8 Miscellaneous...2-13 2.8.1 Display...2-13 2.8.2 Δ Power...2-13 2.8.3 Probe Calibration...2-14 2.8.4 Memory...2-14 2.8.5 Mechanical...,...2-14 2.8.6 Optical Interface Port...2-14 2.9 Environmental...2-14 2.10 /ί Safety...2-15 2.11 10:1 Probe VPS200...2-17 2.11.1 Safety...2-17 2.11.2 Electrical specifications...2-17 2.11.3 Environmental...2-17 2.12 Electromagnetic Immunity...2-1.8 3 Circuit Description,,...,.,»...,...,...,...,...3-1 3.1 Introduction...3-3 3.2 Block Diagram...3-3 3.3 Start-up Sequence, Operating Modes...3-7 3.4 Detailed Circuit Descriptions...3-9 3.4.1 Scope Channel A - Scope Channel B...3-9 3.4.2 Meter/Ext Trigger Channel...3-12 3.4.3 Sampling&Triggering (S-ASIC)...3-15 3.4.4 S-ASIC supply...3-19 3.4.5 ADC’s...3-19 3.4.6 Digital Control...>...3-20 3.4.7 LCD Control...3-22 3.4.8 Power...3-23 3.4.9 Slow ADC, RS232 Serial Interface LCD Backlight...3-28 4 Performance Verification... 4-1 4.1 Introduction...4-3 4.2 Equipment Required For Verification...4-3 4.3 General Instructions...4-3 4.4 Operating Instructions...4-4 4.4.1 Resetting the test tool...4-4 4.4.2 Navigating through menu’s...4-4 4.4.3 Creating Test Tool Setup!...4-5 4.5 Display and Backlight Test...4-5 4.6 Scope Input A&B Tests... 4-7 4.6.1 Input A&B Vertical Accuracy Test... 4-7 4.6.2 Input A&B DC Voltage Accuracy Test... 4-9 4.6.3 Input A&B AC Voltage Accuracy Test (LF)... 4-11 4.6.4 Input A&B AC Coupled Lower Frequency Test... 4-12 4.6.5 Input A and B Peak Measurements Test... 4-13 4.6.6 Input A&B Frequency Measurement Accuracy Test... 4-14 4.6.7 Input A&B Phase Measurements Test... 4-15 4.6.8 Time Base Test... 4-16 4.6.9 Input A Trigger Sensitivity Test... 4-18 4.6.10 Input A AC Voltage Accuracy (HF) & Bandwidth Test... 4-19 4.6.11 Input B Trigger Sensitivity Test... 4-20 4.6.12 Input B AC Voltage Accuracy (HF) & Bandwidth Test... 4-21 4.6.13 Video test using the Video Pattern Generator 4-22 4.6.14 Video test using SC600 Scope Calibration Option ... 4-25 4.7 External Trigger Level Test... 4-27 4.8 Meter (DMM) Tests... 4-28 4.8.1 Meter DC Voltage Accuracy Test... 4-28 4.8.2 Meter AC Voltage Accuracy & Frequency Response Test... 4-29 4.8.3 Continuity Function Test... 4-30 4.8.4 Diode Test Function Test... 4-30 4.8.5 Ohms Measurements Test... 4-30 4.9 Probe Calibration Generator Test... 4-32 5 Calibration Adjustment... 5-1 5.1 General... 5-3 5.1.1 Introduction... 5-3 5.1.2 Calibration number and date... 5-3 5.1.3 General Instructions... 5-3 5.1.4 Equipment Required For Calibration... 5-4 5.2 Calibration Procedure Steps... 5-4 5.3 Starting the Calibration... 5-4 5.4 Contrast Calibration Adjustment... 5-6 5.5 Warming Up & Pre-Calibration... 5-7 5.6 Final Calibration... 5-8 5.6.1 Input A LF-HF Gain... 5-8 5.6.2 Input B LF-HF Gain... 5-9 5.6.3 input A&B LF-HF Gain... 5-11 5.6.4 Input A&B Position... 5-12 5.6.5 Input A&B Volt Gain... 5-13 5.6.6 DMM Volt Gain... 5-14 5.6.7 Input A& B, and DMM Zero... 5-15 5.6.8 DMM Ohm Gain... 5-16 5.6.9 Calculate Gain... 5-17 5.7 Save Calibration Data and Exit... 5-17 5.8 Probe Calibration... 5-19 6 Disassembling the Test Tool... 6-1 6.1. Introduction... 6-3 6.2. Disassembly & Reassembly Procedures... 6-3 6.2.1 Required Tools... 6-3 6.2.2 Removing the Tilt Stand & Hang Strap... 6-3 6.2.3 Replacing the Side-Strap, Changing the Side-Strap Position... 6-3 6.2.4 Opening the Test Tool, Removing the Battery... 6-3 6.2.5 Removing the Main PCA Unit and the Fan...6-5 6.2.6 Removing the Display Assembly...6-6 6.2.7 Replacing the LCD Window/Decaf...6-7 6.2.8 Removing the Keypad and Keypad Foil...6-7 6.2.9 Disassembling the Main PCA Unit...6-7 6.2.10 Reassembling the Main PCA Unit...6-8 6.2.11 Reassembling the Test Tool...6-9 7 Corrective Maintenance...7-1 7.1 Introduction...7-3 7.2 Starting Fault Finding...7-4 7.3 Charger Circuit...7-5 7.4 Starting with a Dead Test Tool...7-7 7.4.1 Test Tool Completely Dead...7-7 7.4.2 Test Tool Software Does not Run...7-8 7.4.3 Software Runs, Test Tool not Operative...7-8 7.5 Miscellaneous Functions...7-8 7.5.1 Display and Back Light...7-8 7.5.2 Fly Back Converter 7-10 7.5.3 Slow ADC, +3V3SADC...7-11 7.5.4 Keyboard...7-12 7.5.5 Optical Port (Serial RS232 Interface)...7-13 7.5.6 Channel A, Channel B Measurements...7-13 7.5.7 Meter Channel (Ext Trigger Probe Cal)...7-15 7.5.8 Input Signal Acquisition...7-17 7.5.9 ADC’s...,...7-19 7.5.10 Digital Control & Memory...7-20 7.5.11 Buzzer Circuit...7-20 7.5.12 RAM Test...7-21 7.5.13 Power ON/OFF...7-22 7.5.14 Battery...7-22 7.6 Loading Software 7-23 8 List of Replaceable Parts...8-1 8.1 Introduction...8-3 8.2 How to Obtain Parts...8-3 8.3 Service Centers...8-3 8.4 Final Assembly Parts...8-4 8.5 Main PCA Unit Parts ...8-6 8.6 Main PCA Parts...8-8 8.7 Accessories 8-30 9 Circuit Diagrams ...9-1 9.1 Introduction...9-3 9.2 Tracing signals in circuit diagrams...9-3 9.3 Locating Parts & Test Points...9-3 9.4 Diagrams...9-6 10 Modifications...10-1 10.1 General...10-3 10.2 Software modifications...10-3 10.3 Hardware modifications...10-3 10.4 Main PCA Unit Versions Software Versions...10-4

show more

Service manual
Manual type:
Service manual
Pages:
86
Size:
2.2 MB
Language:
english
Revision:
revised
Manual-ID:
PN 4822 872 05391
Date:
October 2009
Quality:
Electronic document, no scan, very well readable.
Upload date:
Aug. 5, 2017
MD5:
ec364392-c8e1-c6d0-5dae-ec0fbfc225e6
Downloads:
4443

Information

1 2 3 4 Title Page Safety Instructions... 1-1 1.1 Introduction...1-3 1.2 Safety Precautions...1-3 1.3 Caution and Warning Statements...1-3 1.4 Symbols ...1-3 1.5 Impaired Safety...1-4 1.6 General Safety Information...1-4 Characteristics ... 2-1 List of Replaceable Parts ... 3-1 3.1 Introduction...3-3 3.2 How to Obtain Parts...3-3 3.3 Final Assembly Parts ...3-4 3.4 Main PCA Unit Parts ...3-6 3.5 Accessories 3-8 Performance Verification ... 4-1 4.1 Introduction...4-3 4.2 Equipment Required For Verification ...4-3 4.3 General Instructions ...4-3 4.4 Operating Instructions...4-4 4.4.1 Resetting the test tool ...4-4 4.4.2 Navigating through menu’s ...4-4 4.4.3 Creating Test Tool Setup1...4-5 4.5 Display and Backlight Test...4-5 4.6 Scope Input A&B Tests ...4-7 4.6.1 Input A&B Vertical Accuracy Test ...4-7 4.6.2 Input A&B DC Voltage Accuracy Test...4-9 4.6.3 Input A&B AC Voltage Accuracy Test (LF) ...4-11 4.6.4 Input A & B AC Coupled Lower Frequency Test...4-12 4.6.5 Input A and B Peak Measurements Test...4-13 4.6.6 Input A&B Frequency Measurement Accuracy Test ...4-14 4.6.7 Input A&B Phase Measurements Test...4-15 4.6.8 Time Base Test ...4-16 4.6.9 Input A Trigger Sensitivity Test...4-17 4.6.10 Input A AC Voltage Accuracy (HF) & Bandwidth Test ...4-19 4.6.11 Input B Trigger Sensitivity Test ...4-20 4.6.12 Input B AC Voltage Accuracy (HF) & Bandwidth Test ...4-21 4.6.13 Video test using the Video Pattern Generator 4-22 4.6.14 Video test using SC600 Scope Calibration Option ...4-24 4.7 External Trigger Level Test ...4-27 4.8 Meter (DMM) Tests...4-28 4.8.1 Meter DC Voltage Accuracy Test ...4-28 4.8.2 Meter AC Voltage Accuracy & Frequency Response Test ...4-29 4.8.3 Continuity Function Test...4-30 4.8.4 Diode Test Function Test ...4-30 4.8.5 Ohms Measurements Test...4-30 4.9 Probe Calibration Generator Test ...4-32 5 Calibration Adjustment ... 5-1 5.1 General...5-3 5.1.1 Introduction ...5-3 5.1.2 Calibration number and date...5-3 5.1.3 General Instructions...5-3 5.1.4 Equipment Required For Calibration ...5-4 5.2 Calibration Procedure Steps...5-4 5.3 Starting the Calibration ...5-4 5.4 Contrast Calibration Adjustment ...5-6 5.5 Warming Up & Pre-Calibration...5-7 5.6 Final Calibration ...5-8 5.6.1 Input A LF-HF Gain ...5-8 5.6.2 Input B LF-HF Gain ...5-9 5.6.3 Input A&B LF-HF Gain ...5-11 5.6.4 Input A&B Position ...5-12 5.6.5 Input A&B Volt Gain ...5-13 5.6.6 DMM Volt Gain ...5-14 5.6.7 Input A& B, and DMM Zero...5-15 5.6.8 DMM Ohm Gain ...5-16 5.6.9 Calculate Gain...5-17 5.7 Save Calibration Data and Exit...5-17 5.8 Probe Calibration ...5-19 6 Disassembling the Test Tool... 6-1 6.1. Introduction...6-3 6.2. Disassembly & Reassembly Procedures ...6-3 6.2.1 Required Tools ...6-3 6.2.2 Removing the Tilt Stand & Hang Strap...6-3 6.2.3 Replacing the Side-Strap, Changing the Side-Strap Position...6-3 6.2.4 Opening the Test Tool, Removing the Battery...6-3 6.2.5 Removing the Main PCA Unit and the Fan...6-5 6.2.6 Removing the Display Assembly ...6-6 6.2.7 Replacing the LCD Window/Decal ...6-7 6.2.8 Removing the Keypad and Keypad Foil...6-7 6.2.9 Disassembling the Main PCA Unit...6-7 6.2.10 Reassembling the Main PCA Unit...6-8 6.2.11 Reassembling the Test Tool ...6-9

show more