.....obsolete user manuals, a lot of repair manuals, free service manuals, rare schematic diagrams, usefull service instructions, pdf books, how to repair instructions, lost operating manuals, old handbooks, tons of part lists, hidden service bulletins, your instruction books, informative repair tips, complete disassembly routines.....


What are you looking for?


Fluke - 341A - Calibrator
Manufacturer:
Equipment:
341A
Date:
1969
Category:
Group:
Sub Group:
DC Voltage Calibrator

Information

The Fluke Model 341Ä and Model 343A' DC Voltage Calibrator provide dc voltages of 0 to 1100 volts in three ranges. Voltages are selected by eleven-position decade switches, which provide in-line, digital readout of the instrument output voltage. The Model 341A employs six-dial readout» with 1 ppm resolution, and the Model 343A employs seven-dial readout, with 0.1 ppm resolution. A controlled current limiter, a fixed current limiter, and an electronic crowbar circuit provide protection against instrument malfunction and operator error. Output current or voltage, depending on function desired, are continuously monitored by a front panel meter. The instruments are designed for rack-mount installation, using the mounting brackets supplied, and are equipped with resilient feet and tilt-down bail for field or bench use.

show more

2 Manuals

Service and user manual
Manual type:
Service and user manual
Pages:
98
Size:
8.5 MB
Language:
english
Revision:
Manual-ID:
293951
Date:
Quality:
Scanned document, all readable.
Upload date:
Feb. 10, 2016
MD5:
4dccc19a-b788-5f56-439b-8480d49f98d3
Downloads:
2103

Information

I INTRODUCTION AND SPECIFICATIONS... 1-1 1-1. introduction ... 1-1 1-5. Electrical Specifications... 1-1 1-6. Environmental Specifications... 1-2 1-7. Mechanical Specifications ... 1-3 1-8. General Specifications... 1-3 II OPERATING INSTRUCTIONS... 2-1 2-1. Introduction ... 2-1 2-4. Operating Features. . ... 2-1 2-6. Controls, Terminals and Indicators ... 2-1 2-8. Input Power Requirements ... 2-1 2-10. Preliminary Operation ... 2-1 2-12, AC Line Connections... 2-1 2-14. Sense Connections... 2-1 2-18. Current Limit Operation... 2-5 2-20. Overload Protection... 2-5 2-23. Mechanical Zero Adjustment... 2-5 2-25.. Operation as a Voltage Calibrator 2-5 2-27. Applications ... 2-6 2-29. Operation as a Differential Voltmeter... 2-6 2-31. Operation as a 10 ppm Source... 2-6 III THEORY OF OPERATION... 3-1 3-1. Introduction... 3-1 3-3. Block Diagram Analysis... 3-1 3-12. Circuit Analysis... 3-3 3-13. +15 Volt Reference and Auxiliary Supplies... 3-3 3-16. Chopper-Stabilized Amplifier 3-3 3-20. Series Regulator... 3-3 3-23. Controlled Current Limiter... 3-4 3-27. Negative Voltage Limiter... 3-4 3-29. Sink Supply and Crowbar... 3-4 3-34. Control Circuit... 3-5 3-38. High Voltage Power Supply... 3-6 3-40. Meter Circuit... 3-6 3-42. Beta String... 3-6 IV MAINTENANCE ...4-1 4-i. Introduction ... ...4-i 4-3. Service information ...4-1 4-6. Test Equipment. ...4-1 4-8. General Maintenance ...4-1 4-9, Maintenance Access... . 4-1 4-13. Adjustment Locations ...4-3 4-15. Cleaning...4-4 4“!S. 1 15/230 Volt Conversion...4-5 4-20. Fuse Replacement ... ...4-5 4-22. Lamp Replacement. ... . 4-5 4-24. Performance Tests...- 4-6 4-26. Line Regulation. ...4-6 4-28. Load Regulation...4-6 4-30, Ripple ...4-7 4-32. Output Voltage Accuracy...4-8 4-36. Troubleshooting ...4-8 4-39. Test Point Resistance Check...4-8 4-41. Standby Test...4-8 4-43. Auxiliary Supply Voltages...4-9 4-45. Power-On Test...440 4-47. Chopper Amplifier 4-11 4-49. Series Regulator ...4-11 4-51. Controlled Current Limiter ...4-12 4-53. Crowbar...4-12 4-55. High Voltage Power Supply 4-12 4-57. Beta String ... . 4-13 4-59. Pane! Meter ...4-13 4-61. Model 341A Calibration ...4-14 4-63. Preliminary Operations... 4-14 4-64. Reference Voltage Adjustment. ...4-14 4-65. Zero Output Adjustments ...4-14 4-66. Beta String Linearity Adjustments ... 4-14 4-67. Range Adjustments . ...4-14 4-68. Calibration Verification ...4-15 4-70. Model 343A Preliminary Calibration...4-15 4-72. Preliminary Operations ...'4-15 4-73. Reference Voltage Adjustment ... : 4-16 4-74. Zero Output Adjustments...4-16 4-75. Beta String Linearity Adjustments...4-16 4-76, Temperature Stabilization...4-17 4-77. Model 343A Final Calibration ...4-17 4-79. Zero Output Adjustments...4-17 4-80. Beta String Linearity Adjustments...4-17 4-83. Range Adjustments...4-19 4-84, Calibration Verifications ...4-20 V LIST OF REPLACEABLE PARTS ...5-1 5-1. Introduction ... . 5-1 5-3. Column Description...5-1. 5-5. How To Obtain Parts ...5-2 5-8. List of Abbreviations ...5-2 5-9. Serial Number Effectivity ...5-45 7 GENERAL INFORMATION... · ?-l 8 SCHEMATIC DIAGRAMS...8-1

show more

Service and user manual
Manual type:
Service and user manual
Pages:
100
Size:
4.2 MB
Language:
english
Revision:
Manual-ID:
Date:
April 1973
Quality:
Scanned document, reading partly badly, partly not readable.
Upload date:
Jan. 9, 2025
MD5:
f8be6e55-5d8e-0ad2-34cf-e4afc0c57c04
Downloads:
113