Kenwood - CS-1012 - Oscilloscope
Manufacturer:
Image 1 of 2
If you have any other photos or manuals for the
Kenwood CS-1012
you can
upload the files here.
Equipment:
CS-1012
Date:
1991
Category:
Group:
Sub Group:
Information
Vertical axis has high sensitivity and wide bandwidth and especially covers fully specified frequency response at 2mV/div for all models.
CS-1022, 1021 ;
Dual Trace
1 mV/div : DC to 10 MHz, -3 dB 2mV/div : DC to 20 MHz, -3 dB
CS-1012 ; Dual Trace
1 mV/div : DC to 7 MHz, -3 dB 2mV/div : DC to 10 MHz, -3 dB
CS-1020 ; Single Trace
1 mV/div : DC to 10 MHz, -3 dB 2mV/div : DC to 20 MHz, -3 dB
CS-1010 ; Single Trace
1 mV/div : DC to 7 MHz, -3 dB 2mV/div : DC to 10 MHz, -3 dB
• Vertical sensitivity range is selectable from 1 mV/div to 5V/div with rotary switch continuously.
• Time base permits the high sweep speed.
CS-1022, 1020; 20nsec/div (x10 MAG)
CS-1021, 1012, 1010; 50nsec/div (x10 MAG)
• Vertical sensitivity error and sweep rate error are ±3% and accurate measurements are provided.
• The 150 mm rectangular CRT with internal graticule provides high brightness and accurate measurements, free of parallax error.
CS-1022, 1020; domed mesh type CRT with post deflection acceleration and high brightness phosphors (acceleration voltage; 6 kV).
CS-1021, 1012, 1010; high brightness CRT (acceleration voltage; 2 kV).
• For convenience in making rise time measurements, the 0%, 10%, 90% and 100% levels are marked on the graticule scale of the CRT.
• Trace rotation is electrically adjustable from the front panel.
• By SCALE ILLUM control, the waveform is easy observed in the dark and the photograph of the waveform is easy provided. (Except CS-1021)
• Selectable AUTO FREE RUN function provides sweep without trigger input signal.
• The FRAME-LINE switch provides selection of sync pulse for sweep triggering from small amplitude to large amplitude without adjusting when viewing composite video waveforms.
• For CS-1022, 1021 and 1012, vertical mode automatically provides the trigger signal with TRIG SOURCE and V. MODE switches.
• X-Y operation is easy provided by one-touche.
CS-1022, 1021, 1012; CH1 Y axis,
CH2 X axis CS-1020, 1010; VERT INPUT Y axis
EXT TRIG INPUT X axis
• CS-1022 and 1012 are provided with CH1 OUTPUT terminal to monitor input signal of CH1.
• CS-1020 and 1010 are provided with VERT OUTPUT terminal to monitor input signal of VERT INPUT.
3 Manuals
User manual
Manual type:
User manual
Pages:
31
Size:
5.9 MB
Language:
english
Revision:
Manual-ID:
B50-7570
Date:
December 1991
Quality:
Scanned document, all readable.
Upload date:
May 17, 2020
MD5:
75cc6fd6-6c3e-d817-f2e8-277923300051
Uploader:
Fabio
Downloads:
1939
Service manual
Manual type:
Service manual
Pages:
55
Size:
21.6 MB
Language:
english
Revision:
Manual-ID:
Date:
Quality:
Scanned document, reading partly badly, partly not readable.
Upload date:
Dec. 28, 2020
MD5:
2d1f213f-140e-5270-bf13-823c7c21bba5
Uploader:
Guidopianino
Downloads:
1489
Service manual
Manual type:
Service manual
Pages:
87
Size:
11.9 MB
Language:
english
Revision:
Manual-ID:
Date:
Quality:
Scanned document, all readable.
Upload date:
Dec. 28, 2020
MD5:
1103c56c-9610-3dcd-cd3c-9fafffac145b
Downloads:
1881