.....obsolete user manuals, a lot of repair manuals, free service manuals, rare schematic diagrams, usefull service instructions, pdf books, how to repair instructions, lost operating manuals, old handbooks, tons of part lists, hidden service bulletins, your instruction books, informative repair tips, complete disassembly routines.....


What are you looking for?


Metron - QA-IDS - Analyzer
Manufacturer:
Equipment:
QA-IDS
Date:
1998
Category:
Group:
Sub Group:

Information

METRON’s QA-IDS Infusion Pump Tester is a precision instru- ment, designed for use by trained service technicians, for testing all types of infusion pumps according to International Electrotechnical Commission (IEC) Draft Standard 62.D (IEC 601.2.24). Tests include: • volumetric tests • bolus tests • occlusion alarm tests QA-IDS is capable of detecting a minimum volume variation of one microliter in a range of 0.10 milliliter per hour (ml/hr) to 1000.0 ml/hr. Flow measurements are taken every 30 seconds, so that the measurements are independent of the infusion pump’s flow rate. Test results, shown in the QA-IDS's LCD display, can be printed out directly, or transferred to a PC via the PRO-Soft QA-IDS test automation Software PRO-Soft lets you design test protocols, remotely control the QA-IDS and store the test results.

show more

1 Manual

Service and user manual
Manual type:
Service and user manual
Pages:
62
Size:
385.4 KB
Language:
english
Revision:
Manual-ID:
15035
Date:
January 1998
Quality:
Electronic document, no scan, very well readable.
Upload date:
Aug. 16, 2019
MD5:
4a4545b2-4d60-c7c6-758c-0e61a99848a0
Downloads:
533

Information

MANUAL REVISION RECORD...5 1. INTRODUCTION...7 1.1 QA-IDS Features ...7 1.2 Specifications...7 1.3 General Information...8 2. INSTALLATION...9 2.1 Receipt, Inspection and Return...9 2.2 Setup...10 2.3 Power ...10 2.4 PRO-Soft QA-IDS 10 3. OPERATING QA-IDS 13 3.1 Control Switches and Connections...13 3.2 Key Pad Functions...14 3.3 Menu and Function Keys...14 3.4 Display Menus and Messages ...15 3.5 Printing Test Reports...20 3.6 Operator Maintenance...22 4. INFUSION PUMP TESTING...23 4.1 Introduction...23 4.2 Test Preparation...23 4.3 Occlusion Pressure/ Bolus Volume Testing ...25 4.4 Infusion Flow Rate and Volume Testing...26 5. CONTROL AND CALIBRATION...29 5.1 Required Test Equipment...29 5.2 Adjusting the Display Contrast ...29 5.3 Testing Power Supply to IDS...29 5.4 Testing Pressure Gauge Accuracy...30 5.5 Testing Flow Rate Accuracy...30 5.6 Checking the Battery Backup...31 6. COMPONENT FUNCTIONS AND PARTS...33 6.1 Theory of Operation...33 6.2 Power Supply 33 6.3 Printer Output...33 6.4 Serial Port...34 6.5 Microprocessor...34 6.6 Pressure Gauge...34 6.7 Pump...34 6.8 Stepper Motor/Drivers...34 6.9 Control Panel...35 6.10 Component Parts...35 APPENDIX A: DIAGRAMS...39 Processor board Component Location...41 6.10.1 Processor board Schematic Diagram 1 ...42 6.10.2 Processor board Schematic Diagram 2 (Digital Part) ...43 6.10.3 Processor board Schematic Diagram 3 (CPU) ...44 6.10.4 Processor board Schematic Diagram 4 (Memory) ...45 6.10.5 Processor board Schematic Diagram 5 (RS232C and Printer) ...46 6.10.6 Processor board Schematic Diagram 6 (Digital Outputs) ...47 6.10.7 Processor board Schematic Diagram 7 (Digital Inputs) ...48 6.10.8 Processor board Schematic Diagram 8 (A/D) ...49 6.10.9 Processor board Schematic Diagram 9 (Stepper Motor and Drivers) ...50 6.10.10 Processor board Schematic Diagram 10 (Pressure Sensor and Temperature) ...51 6.10.11 Processor board Schematic Diagram 11 (Main Part) ...58 6.10.12 Processor board Schematic Diagram 12 (Keyboard, Pressure Sensor and Pump Index) ...59 APPENDIX B: ERROR REPORT FORM QA-IDS 62 APPENDIX C: SUGGESTION FORM QA-IDS 65

show more