Information
The main purpose of the measuring coupler is to provide the
reflection alarm unit with rectified signal of the output
power to the antenna and reflected power. Two coupled
signals are also made available for testing with, for
example, a spectrum analyser.
The input is to connector J2, the output from connector J1.
The samples are obtained via four directional couplers. The
rectified signal are available at two levels via connector
J5. The other samples are available from separate
connectors, J3 and J4.
Typical value:
Middle frequency 465 MHz
Forward Po = 30 W Uo = 0,427V
Backward Pr = 3.0 W Uo = 0,477V
Refl. fact. 20
J3 and J4 -40dB