The Simpson 467 Digital Multimeter offers the best of both
worlds, a unique combination of digital and analog LCD
display (Liquid Crystal Display) used to analyze both steady
and pulsating signals, differential positive and negative
peak-holding capability, and fast pulse detection and
indication. In addition to the traditional voltage, current
and resistance measurements of a 3Ά digit multimeter, this
versatile Instrument can actually replace the oscilloscope
and the logic probe'used in many applications.
In the differential peak mode, the Simpson 467 (hereafter
referred to as the 467 or the Instrument) can make percent
modulation and signal tracing measurements. In the pulse
detection mode, the Instrument offers visual and/or audible
indication of the presence of pulses and logic levels. The
LCD analog bargraph display provides a rapid indication of
either voltage or current signal levels, offering the
advantages of nulling and peaking from' an analog meter.
Other standard features of the 467 include: true RMS
measuring capability, basic 0.1% DC voltage accuracy,
continuity detection with both visual and audible
indications, high voltage transient protection, excellent
overload capability, double-fuse protection, and designed to
meet the requirements of UL-1244, Safety Standard for
Electrical and Electronic Measuring and Testing Equipment.
3 Manuals
User manual
Manual type:
User manual
Pages:
50
Size:
5.3 MB
Language:
english
Revision:
1st edition
Manual-ID:
6-112923
Date:
Quality:
Scanned document, all readable.
Upload date:
July 17, 2010
MD5:
0f2d6f0d-1ef8-81e6-fc5d-e04d377a5277
Downloads:
2424
Service manual supplement
Manual type:
Service manual supplement
Pages:
12
Size:
1.4 MB
Language:
english
Revision:
Manual-ID:
6-112812
Date:
Quality:
Scanned document, all readable.
Upload date:
July 17, 2010
MD5:
9398e6b0-8b86-bf15-ab2f-692da72489b2
Downloads:
1979
Service and user manual
Manual type:
Service and user manual
Pages:
38
Size:
3.9 MB
Language:
english
Revision:
first edition
Manual-ID:
6-112923
Date:
Quality:
Scanned document, reading partly badly, partly not readable.
Upload date:
Nov. 23, 2014
MD5:
188103c1-4529-ca9c-19b8-61073b2d63e1
Downloads:
1147
Information
SECTION I
INTRODUCTION ................................................
1.1 GENERAL ...........................................
1.2 ITEMS AND ACCESSORIES...........
1.3 SAFETY CONSIDERATIONS .....
1.4 TECHNICAL DATA .........................
SECTION II
INSTALLATION ..................................................
2.1 GENERAL ..........................................
2.2 UNPACKING AND INSPECTION .
2.3 WARRANTY........................................
2.4 SHIPPING ............................................
2.5 POWER SOURCE REQUIREMENTS .............................
2.6 INSTALLATION ...............................
SECTION III
CONTROLS. CONNECTORS,
AND INDICATORS ............................................
3.1 GENERAL ..........................................
3.2 FRONT AND SIDE
PANEL DESCRIPTION ...................
SECTION IV
OPERATING INSTRUCTIONS .......................
4.1 GENERAL ..........................................
4.2 BATTERY ............................................
4.3 CURRENT RANGE FUSES............
4.4 DC VOLTAGE MEASUREMENTS
4.5 AC VOLTAGE MEASUREMENTS
4.6 DC CURRENT MEASUREMENTS
4.7 AC CURRENT MEASUREMENTS
4.8 RESISTANCE MEASUREMENT ..
4.9 CONTINUITY MEASUREMENTS .
4.10 DIODE TEST .....................................
4.11 PEAK HOLD ..................................... 4-12
4.12 ABSOLUTE VALUE
PULSE DETECTOR .........................4-13
4.13 ANALOG BARGRAPH DISPLAY . 4-15 SECTION V
THEORY OF OPERATION............................... 5-1
5.1 OVERALL SYSTEM ......................... 5-1
5.2 INPUT CIRCUITS ............................. 5-4
5.3 SPECIAL CIRCUITS . ........................ 5-7
SECTION VI
APPLICATIONS
.................................................. 6-1
6.1 GENERAL .......................................... 6-1
6.2 MEASUREMENT OF LOW FREQUENCY WAVEFORMS........ 6-1
6.3 PEAKING AND NULLING ........... 6-3
6.4 USE OF THE 467
AS A LOGIC PROBE....................... 6-4
6.5 LOCATION OF WIRING
INTERM IlTENTS ............................. 6-6
6.6 PEAK IN-RUSH CURRENT MEASUREMENTS
........................... 6-7
SECTION Vn
OPERATOR MAINTENANCE.....................7-1
7.1 GENERAL............................................... 7-1
7.2 COVER REMOVAL ......................... 7-1
7.3 BATTERY INSTALLATION AND REPLACEMENT PROCEDURE .. 7-1
7.4 FUSE REPLACEMENT ................ . 7-2
7.5 CARE ................................................... 7-3
SECTION VIII
SERVICING INSTRUCTIONS ......................... 8-1
8.1 GENERAL ......................................... 8-1
8.2 TROUBLESHOOTING ..................... 8-1
8.3 REPLACEMENT PARTS AND SCHEMATIC DIAGRAM ..............- 8-4