Sencore - PS163 - Oscilloscope
Manufacturer:
Image 1 of 2
If you have any other photos or manuals for the
Sencore PS163
you can
upload the files here.
Equipment:
PS163
Date:
1973
Category:
Group:
Sub Group:
Information
The rapid changes which are taking place in electronics
today are causing engineers, designers, technicians and
instructors to take a critical look at the equipment
they will need to keep pace with these changes. The
dramatic increase of solid state components being
used has created different test equipment requirements
than the tube circuits of the past. The increasing
use of Field Effect Transistors and Integrated
Circuits are other important facts to consider.
What do all these changes mean to the area of oscilloscopes?
First, the lower potentials used in these circuits
and the much lower signal levels call for an instrument
with increased sensitivity if it is to be practical
for the design and servicing of solid state circuits.
More emphasis is being placed on critical waveform
analysis and the comparison of waveforms, particularly
the timing of “concurrent” waveforms present
in much of the equipment used today. This includes
the fields of television, computors, and particularly the
educational field. The instrument to fill these applications
requires triggered operation for the meaningful
measurement of pulse time and concurrent
waveform comparison. It must have full dual trace
capability if any comparisons are to be made. In addition,
it must be simple to operate and provide full
versatility.
The PS163 fulfills these requirements and more. Ease
of operation has been one of the important design
considerations of the PS163. The Free Running sweep
feature has been added to simplify operation for those
not familiar with triggered sweep scopes. The PS163
incorporates the latest in solid state design to assure
long and trouble free service. A glance at other
features of this practical instrument will point out its
many uses and advantages.
FEATURES
*** EXTREMELY STABLE triggered sweep with
full bandwidth capability in both automatic and manual
triggered modes, PLUS free running capability for
use as a sync-sweep service oscilloscope.
*** COMPLETE DUAL TRACE capability with
pushbutton selection of CHANNEL A, CHANNEL
B, DUAL ALTERNATE or DUAL CHOPPED displays,
PLUS Sencore’s exclusive VECTOR mode for
direct display of phase relationships.
*** VERTICAL INPUT SENSITIVITY of 5mV/cm
direct. 50mV/cm with low capacity probe. Input
attenuator calibrated to read directly when using low
capacity probe. Gain continuously variable between
attenuator positions.
*** BANDWIDTH of DC to 8MHz-3db, useable to
15MHz. Negligible overshoot, typically 1% or less.
*** CALIBRATED TIME BASE rates from .1 microsecond
to .1 second per division in 19 positions
plus TVV, TVH, 60Hz and EXT. positions. Sync
separator automatically added in TVV and TVH
sweep positions for rock solid display of complex TV
waveforms. 60Hz and EXT. positions provided for
line sweep and use with sweep generators.
*** FRONT PANEL correlation between sweep
speed and frequency for ease of operation. Sweep
speed continuously variable between steps. 5X magnification
provided.
*** PUSHBUTTON SELECTION of trigger sources:
Internal Channel A, Internal Channel B, Line or External.
*** HIGH INPUT IMPEDANCE Qf 10 megohm
shunted by l l p f using low capacity probe. 1 megohm
shunted by 35pf at input terminals.
*** FULLY PROTECTED Field Effect Transistor
input. Maximum input voltage with the Low Capacity
Probe is 5000 volts peak to peak AC, or 1000 volts
DC. This allows measurements of signals that can
destroy other oscilloscopes.
*** ILLUMINATED full size 10 x 10cm grid PLUS
illuminated vector grid at the flip of a switch. No
separate grids to change or become misplaced.
*** RETRACTABLE TIP on special 5KV low capacity
probe for ease of connection in hard to reach
places.
*** SOLID STATE for dependable accuracy and
reliability. 2KV regulated CRT supply wi
5 Manuals
User manual
Manual type:
User manual
Pages:
26
Size:
8.1 MB
Language:
english
Revision:
Manual-ID:
687
Date:
Quality:
Scanned document, all readable.
Upload date:
May 4, 2014
MD5:
9f493dbd-0fbe-8002-f611-ec0ab9753e75
Downloads:
862
Datasheet
Manual type:
Datasheet
Pages:
2
Size:
1.0 MB
Language:
english
Revision:
Manual-ID:
939P
Date:
Quality:
Scanned document, all readable.
Upload date:
May 4, 2014
MD5:
3a2f8d1c-42c0-c9b4-4415-d8c4094d77b2
Downloads:
658
Partlist
Manual type:
Partlist
Pages:
4
Size:
788.1 KB
Language:
english
Revision:
Manual-ID:
809
Date:
Quality:
Scanned document, all readable.
Upload date:
May 4, 2014
MD5:
362c64e8-dc0d-5896-1518-7e708172b0c6
Downloads:
652
Schematics diagram
Manual type:
Schematics diagram
Pages:
1
Size:
845.7 KB
Language:
english
Revision:
Manual-ID:
Date:
July 1973
Quality:
Scanned document, all readable.
Upload date:
May 4, 2014
MD5:
9e633c18-e9fa-f015-4a75-c50b076bff43
Downloads:
761
Service manual
Manual type:
Service manual
Pages:
22
Size:
7.0 MB
Language:
english
Revision:
Manual-ID:
636
Date:
Quality:
Scanned document, all readable.
Upload date:
May 4, 2014
MD5:
dc2d9d82-bb7f-fc9f-6589-10793286049b
Downloads:
782