Tektronix - WFM 601E - Wave Analyzer
Manufacturer:
Equipment:
WFM 601E
Date:
Category:
Group:
Sub Group:
Information
The waveform monitors measure and display 4:2:2 component
serial digital
signals. The waveform monitors display serial digital
signals as the familiar
component signals and in a variety of standard measurement
modes. You can use
the EDH (Error Detection and Handling) system and the suite
of automated
checks of the serial digital format to verify data integrity.
Most of the features listed in this section are common
across all three waveform
monitors. Where a feature applies only to a specific model,
the model is in
parentheses following the feature description. The waveform
monitors offer the
following features:
- Two 270 Mbit serial component loop-through inputs
- Digital video standards SMPTE 259M, ITU-R BT.656, and
ITU-R BT.601
- RGB and Y-PB-PR display format for 525 and 625 line signals
- Eye Pattern display with Timing and Voltage Cursors (WFM 601E,
WFM 601M)
- Jitter demodulator with numeric jitter readout and video
correlated jitter
waveform display (WFM 601M)
- Parade or Waveform display of Y, PB, and PR component signals
- RGB and composite Gamut checks with Diamond and Arrowhead
displays
- Field, line, and word select with readout and bright up of
selected lines on
Picture Monitor Out (Y or G Channel) (WFM 601E, WFM 601M)
- SMPTE RP-165 standard EDH indicator for presence
- Digital Waveform and Data displays with Data-cursor
correlation between
display modes (WFM 601M)
- Embedded Audio indentification
- Source-level meter and cable-length readout (WFM 601E, WFM
601M)
Lightning and Vector displays
- Reclocked Serial Component Digital output following A/B
switching
- Video Reference: Internal Serial Component signal (follows
A/B switching)
or external composite
- Audio Lissajous display (WFM 601A)
An expanded feature set is available through menus. You
select menu items with
multi-use bezel buttons and knobs. When you select a menu
item, such as
Voltage Cursors, on-screen labels show the current function
of the bezel buttons
and knobs.
The waveform monitor provides an internal calibrator signal
to set both vertical
and horizontal gain. The calibrator signal is a 700 mV, 100
kHz signal. Press the
CONFIG button and use the bezel knob to select the Calibrate
menu. Press the
CAL SIG button to turn on the calibrator signal.
Service manual
Manual type:
Service manual
Pages:
368
Size:
4.5 MB
Language:
english
Revision:
Manual-ID:
070-9836-05
Date:
Quality:
Electronic document, no scan, very well readable.
Upload date:
May 24, 2014
MD5:
bc27ec8f-4946-3825-8f08-f5aaa7fd7c27
Downloads:
1537