.....obsolete user manuals, a lot of repair manuals, free service manuals, rare schematic diagrams, usefull service instructions, pdf books, how to repair instructions, lost operating manuals, old handbooks, tons of part lists, hidden service bulletins, your instruction books, informative repair tips, complete disassembly routines.....


What are you looking for?

extended search


Fluke 57LFC Calibrator
Manufacturer:
Model:
57LFC
Date:
2004
Class:
Type:
SubType:
System Calibrator

Information

The Fluke Model 57LFC System Calibrator (hereafter called the Calibrator) is a precise instrument that calibrates a wide variety of electrical measuring instruments. This Calibrator maintains a high accuracy over a wide ambient temperature range, and is able to test instruments in harsh environments, eliminating the restriction of calibrating only in a temperature-controlled standards laboratory. With a 57LFC you can calibrate precision multimeters that measure ac or dc voltage, ac or dc current, and resistance. The Calibrator operates in a similar manner to the 57XXA series calibrators. Specifications are provided at the end of this chapter. The Calibrator is a fullyprogrammable precision source of the following: • DC voltage to 220 V. • AC voltage to 220 V rms, with output available from 10 Hz to 100 kHz. • AC and DC current to 2.2 A, with AC output available from 10 Hz to 20 kHz. • Resistance in values from 0 Ω to 19 MΩ in 1 and 1.9x. Features of the Calibrator include the following: • Automatic meter error calculation obtained through using a simple remote adjust. • Programmable entry limits used for restricting the levels that can be remotely keyed into the Calibrator, preventing access to levels that may be harmful to equipment or personnel. • Real-time clock and calendar. • Offset and scaling modes that simplify linearity testing of multimeters. • Standard IEEE-488 (GPIB) Interface, complying with ANSI/IEEE Standards 488.1- 1987 and 488.2-1987. • Internal self-testing and diagnostics of analog and digital functions. • Status LEDs on front panel to indicate standby (yellow), operate (green), high voltage (red), and fault (red and yellow).

show more

Service Manual
Manual type:
Service Manual
Pages:
208
Size:
4.63 Mbytes (4853336 Bytes)
Language:
english
Revision:
Manual-ID:
Date:
unknown
Quality:
Electronic document, no scan, very well readable.
Upload date:
2014 11 29
MD5:
171d891cbaf195552a2fef5e40509212
Downloads:
1370

Information

1 Introduction and Specifications ... 1-1 Introduction ... 1-3 Service Information ... 1-3 Accessories ... 1-4 Low Thermal EMF Test Leads ... 1-4 Rack Mount Kit ... 1-4 Shielded IEEE-488 Cables (Y8021, Y8022, and Y8023) ... 1-4 Contacting Fluke ... 1-5 Specifications ... 1-6 General Specifications ... 1-6 Accuracy Specifications ... 1-7 DC Voltage Accuracy ... 1-7 DC Current Accuracy ... 1-7 Resistance Accuracy ... 1-7 AC Voltage Accuracy ... 1-8 AC Voltage Distortion ... 1-9 AC Current Accuracy ... 1-10 AC Current Distortion ... 1-11 2 Theory of Operation ... 2-1 Introduction ... 2-3 A1 LED PCA ... 2-5 A3 Motherboard PCA ... 2-5 Relay Control and Switch Matrix ... 2-5 LED Control and Output Cables ... 2-10 Signal Buses ... 2-10 Low Volt Buffer ... 2-10 In-guard Power Supplies ... 2-10 Outguard Power Supplies ... 2-11 Miscellaneous Circuits ... 2-11 Troubleshooting Test Points ... 2-12 List of Fuses ... 2-13 A5 Ohms PCA ... 2-13 Precision Resistor Networks ... 2-14 Relay Switch Matrix and Control ... 2-14 Other Control Circuits ... 2-26 Guard Circuits ... 2-26 Compensation Circuits ... 2-27 Monitor ... 2-27 Diagnostics ... 2-29 A6 Digital Synthesis PCA ... 2-33 Precision, Dual Tracking, +/-7 V References ... 2-33 Precision, 28bit, PWM, Dual DAC’s ... 2-33 DC Voltage Operation ... 2-34 DDS Waveform Generation ... 2-34 AC Voltage Operation ... 2-35 DC Current Operation ... 2-35 AC Current Operation ... 2-35 Thermocouple Temperature Measurement ... 2-35 Iso-thermal Block Reference Junction Temperature Measurement ... 2-36 Thermocouple Voltage Measurement: ... 2-36 Thermocouple Temperature Simulation ... 2-36 Analog to Digital Converter ... 2-36 Fault Detection ... 2-36 Digital Control ... 2-37 A7 Current PCA ... 2-37 Detailed Hardware Description of DC/AC Current ... 2-40 Low Current Output Amplifier ... 2-40 Mid-Current Output Amplifier ... 2-41 High Current Output Amplifier ... 2-42 High Current Amplifier Power Supplies (Mongo Supplies) ... 2-43 A8 High Voltage PCA ... 2-44 Detailed Hardware Description of the 22 V Amplifier ... 2-46 Detailed Description of the 220 V Amplifier ... 2-47 Detailed Hardware Description of the High Voltage Regulator ... 2-49 Heat Sink Temperature Measurement ... 2-51 Digital Interface and Control ... 2-51 A9 Out-Guard CPU PCA ... 2-52 Real Time Clock Memory ... 2-52 IEEE-488 Interface ... 2-52 3 Calibration and Verification ... 3-1 Calibration ... 3-3 Procedure Architecture ... 3-3 ZERO ... 3-3 MAIN ... 3-3 DIAG ... 3-3 Calibration Steps ... 3-3 RUN ... 3-4 Instruction Step (INS) ... 3-4 Reference Step (REF) ... 3-4 NOT ... 3-4 Verification Tests ... 3-5 Test Equipment ... 3-5 Calibrator Configuration and Pre-check ... 3-6 DC Voltage Test ... 3-7 AC Voltage Tests ... 3-9 AC Voltage Accuracy Test ... 3-9 Frequency Accuracy Test ... 3-10 DC Current Test ... 3-14 AC Current Test ... 3-15 Current Output Compliance Test ... 3-17 Voltage Output Compliance Test ... 3-17 Harmonic Test Levels for AC Volts ... 3-19 Harmonic AC Current Test ... 3-21 External Trigger ... 3-21 Verification Test Check List ... 3-22 4 Maintenance ... 4-1 Introduction ... 4-3 Replacing the Fuse ... 4-3 Cleaning the Air Filter ... 4-4 Replacing PCA Modules ... 4-6 Cleaning the Exterior ... 4-7 5 List of Replaceable Parts ... 5-1 Introduction ... 5-3 How to Obtain Parts ... 5-3 Service Centers ... 5-4 Parts Lists ... 5-4 6 Schematic Diagrams ... 6-1

show more