.....obsolete user manuals, a lot of repair manuals, free service manuals, rare schematic diagrams, usefull service instructions, pdf books, how to repair instructions, lost operating manuals, old handbooks, tons of part lists, hidden service bulletins, your instruction books, informative repair tips, complete disassembly routines.....


What are you looking for?


Thurlby Thandar Instruments TTI - TSX Series - Power supply
Manufacturer:
Equipment:
TSX Series
Date:
2009
Category:
Group:
Sub Group:

Information

OUTPUT SPECIFICATIONS Output Voltage Range: 0V to 35.3V (35V/10A); 0V to 18.15V (18V/20A). Output Current Range: 0.01A to 10.2A (35V/10A); 0.01A to 20.2A (18V/20A). Output Voltage Setting: Direct keyboard entry or quasi-analogue rotary control; setting resolution 10mV. Output Current Setting: Direct keyboard entry or quasi-analogue rotary control; setting resolution 10mA. Output Mode: Constant voltage or constant current with automatic crossover. Output Switch: Electronic. Preset voltage and current displayed when off. Output Terminals: 4mm terminals on front panel, screw terminals at rear. Sensing: Remote via rear panel screw terminals or direct via shorting strip (supplied). Output Impedance: <1mΩ in constant voltage mode. >5kΩ in constant current mode (voltage limit at max.). Output Protection: Forward protection by Over-Voltage-Protection (OVP) trip; maximum voltage that should be applied to the terminals is 50V. Reverse protection by diode clamp for reverse currents up to 3A. OVP Setting: Direct keyboard entry. OVP Range: 1V to 40V (35V/10A); 1V to 25V (18V/20A). OVP Delay: <200μs Load & Line Regulation: <0.01% of maximum output for 90% load change or 10% line change. Ripple & Noise: <1mV rms typical in constant voltage. <3mA rms typical in constant current. HF Common Mode Noise: Typically <3mV rms, <10mV peak. Transient Response: 20μs to within 50mV of setting for 90% load change. Temperature Coefficient: typically <100 ppm/°C. Protection Functions: Overvoltage trip; regulator overtemperature; sense miswiring. Status Indication: Output off lamp; constant voltage mode lamp; constant current mode lamp; trip message on display. METER SPECIFICATIONS Meter Types: Dual 4 digit meters with 12·5mm (0.5") LEDs. Reading rate 4Hz. Meter Resolution: 10mV, 10mA Meter Accuracy: Voltage 0.2% of reading ± 1 digit, current 0.5% of reading ± 1 digit. KEYBOARD FUNCTIONS Delta Mode: Increase or decrease voltage or current in user-selectable steps. Store/Recall: Store and recall voltage, current and OVP levels from non-volatile memory (25 memories). Interface Selection: Set digital interface type (RS232 or GPIB), baud rate and address.

show more

2 Manuals

User manual
Manual type:
User manual
Pages:
95
Size:
2.0 MB
Language:
english, german, french
Revision:
Issue 12
Manual-ID:
48511-0130
Date:
January 2009
Quality:
Electronic document, no scan, very well readable.
Upload date:
Jan. 14, 2017
MD5:
11956a66-d324-f0e3-355b-44f4cb497be5
Downloads:
573
User manual
Manual type:
User manual
Pages:
95
Size:
867.7 KB
Language:
english, german, french
Revision:
Issue 13
Manual-ID:
48511-0130
Date:
January 2013
Quality:
Electronic document, no scan, very well readable.
Upload date:
Jan. 14, 2017
MD5:
1b73ba08-af63-e918-fc82-89d61fdc62e3
Downloads:
289