.....obsolete user manuals, a lot of repair manuals, free service manuals, rare schematic diagrams, usefull service instructions, pdf books, how to repair instructions, lost operating manuals, old handbooks, tons of part lists, hidden service bulletins, your instruction books, informative repair tips, complete disassembly routines.....


What are you looking for?

extended search


Thermo Electron Corporation Orion 210A+ Level Meter
Manufacturer:
Model:
Orion 210A+
Date:
2003
Class:
Type:
SubType:
Portable pH and ISE Meters

Information

Orion’s Portable Meters are compact, battery operated and microprocessor controlled for all measurement needs. All meters feature a custom digital LCD display, which simultaneously displays temperature along with measurement results. Ideal for field, plant, or laboratory use, each meter is lightweight and designed to fit comfortably in the hand. A flip stand allows easy use in the lab. The Orion 210Aplus is a basic pH meter that features 2 point autocalibration. The Orion 230Aplus is a pH meter that features autocalibration and automatic temperature compensation, millivolt, relative millivolt and (EH) ORP mode. The Orion 250Aplus has all the features of the 230Aplus plus 3 point auto calibration and RS232-C output for use with the Orion 900A printer or other serial peripherals. The Orion 290Aplus adds concentration measurements and an internal datalogging function to make a truly versatile meter for pH or ISE analysis. This manual contains instructions for all four meters. See the calibration and measurement section for details on your particular meter. The general information section contains descriptions of hardware which pertain to all meters. The Temperature Compensation and Troubleshooting sections contain information applicable to all meters.

show more

User Manual
Manual type:
User Manual
Pages:
108
Size:
505.31 Kbytes (517440 Bytes)
Language:
english
Revision:
C
Manual-ID:
233574-001
Date:
2003 01 01
Quality:
Electronic document, no scan, very well readable.
Upload date:
2017 04 14
MD5:
01bc14ca5b210fe5a7b6a37bda1664eb
Downloads:
1953

Information

Chapter I Introduction ... . ... .Chapter II General Information ... .A. Top Panel ... . ... .B. Rear Panel ... . ... .C. Electrode Clip ... . ... . .D. Electrode Storage Compartment ... . ... .E. RS232 Interface ... . ... . .Chapter III Set Up, Self-Test Procedure ... . ... .A. Power Source ... . ... .B. Battery Installation ... . ... .C. Power Up and Self-Test ... . ... .10 D. Electrode Connections ... . ... .11 Chapter IV Orion 210Aplus ... . ... .13 A. Display ... . ... .13 B. Keypad ... . ... .14 C. Self-Test and Checkout Procedure ... . ... .15 D. SETUP Menu ... . ... .16 Resolution ... . ... .16 Slope ... . ... .16 Calibration Buffer Option ... . ... .16 E. Calibration and Measurement Procedures ... . ... .17 pH Measurements ... . ... .17 Autocalibration ... . ... .17 Manual Calibration ... . ... .20 F. Dissolved Oxygen Measurements ... . ... .23 .1 .3 .4 .5 .6 .7 .8 .9 .9 .9 Chapter V Orion 230Aplus ... . ... .25 A. Display ... . ... .25 B. Keypad ... . ... .27 C. Self-Test and Checkout Procedure ... . ... .29 D. SETUP Menu ... . ... .30 E. Calibration and Measurement Procedures ... . ... .32 pH Measurements ... . ... .32 Autocalibration ... . ... .32 Manual Calibration ... . ... .35 ORP Relative to Normal Hydrogen Electrode (NHE) ... . ... .38 Setting ORP Millivolts Offset ... . ... .38 F. Dissolved Oxygen Measurements ... . ... .39 Chapter VI Orion 250Aplus ... . ... .41 A. Display ... . ... .4 B. Keypad ... . ... .43 C. Self-Test and Checkout Procedure ... . ... .45 D. SETUP Menu ... . ... .46 E. Calibration and Measurement Procedures ... . ... .49 pH Measurements ... . ... .49 Autocalibration ... . ... .49 Manual Calibration ... . ... .52 Millivolt Measurements ... . ... .54 ORP Relative to Normal Hydrogen Electrode (NHE) ... . ... .55 Setting ORP Millivolts Offset ... . ... .55 F. Dissolved Oxygen Measurements ... . ... .56 Chapter VII Orion 290Aplus ... . ... .57 A. Display ... . ... .57 B. Keypad ... . ... .59 C. Self-Test and Checkout Procedure ... . ... .61 D. SETUP Menu ... . ... .63 E. Calibration and Measurement Procedures ... . ... .68 pH Measurements ... . ... .68 Autocalibration ... . ... .68 Manual Calibration ... . ... .69 Concentration Measurements ... . ... .72 Millivolt Measurements ... . ... .76 F. Dissolved Oxygen Measurements ... . ... .77 Chapter VIII Temperature Compensation ... . ... .79 Chapter IX Use with Accessories ... . ... .81 A. Use with Printers and Computers ... . ... .81 B. Remote Control ... . ... .82 Chapter X Troubleshooting ... . ... .85 A. Self-Test ... . ... .85 B. Operator Assistance Codes ... . ... .87 C. Troubleshooting Guide ... . ... .92 Chapter XI Instrument Warranty ... .93 Chapter XII Service and Repair ... . ... .97 Chapter XIII Notice of Compliance ... . ... .99 Chapter XIV Ordering Information ... . ... .101 Chapter XV Specification ... . ... .103