Associated Research Incorporated HypotPLUS II 5560DT Test Set
Manufacturer:
No picture available!
Maybe you can
upload
a pic for the
Associated Research Incorporated HypotPLUS II 5560DT ?
If you have any other manuals for the
Associated Research Incorporated HypotPLUS II 5560DT you can
upload
the files here.
Model:
HypotPLUS II 5560DT
Date:
2003
Class:
Type:
SubType:
(AC/DC HIPOT WITH GROUND CONTINUITY CHECK
Information
KEY FEATURES & BENEFITS OF HypotPLUS II
1. No load setup of trip current and output voltage.
This provides the operator with an easy and safe way to set
trip currents and output
voltages since parameters are set without the high voltage
activated.
2.Storage of up to 10 different test programs.
A real benefit for manufacturers that test different
products. This makes it possible store all the various test
parameters required and quickly recall them for each of the
different products that needs to be tested. Program memories
can also be accessed
through the remote control (PLC) port so that a manufacturer
can quickly toggle
through the various programs without going into the set up menu.
3.4.5.6.7.8.to
All parameters for the setups can be adjusted through a
simple menu driven program
by using quick access front panel keys.
The easy to follow setup screens ensure that the operator
correctly sets up all test
parameters.
Tamper proof front panel controls.
This makes it possible to limit user access to the setup
screens so that only authorized
personnel with a security password can change test
parameters. Passwords are
programmable, this ensures that the required test parameters
can not be tampered
with.
Line and load regulation.
This system maintains the output voltage to within 1% from
no load to full load and
over the line voltage range to ensure that test results
remain consistent and within
safety agency requirements..
Posi-Test current sensing system.
This capability makes it possible to ensure that a test item
was properly connected
since the HypotPLUS II can be set to monitor minimum and
maximum levels of
current during a hipot test.
The LCD display allows monitoring of current down to 50
microamps AC and 20
microamps DC.
Many tests only allow a very low level of acceptable leakage
current.
Electronic ramp and dwell settings.
The electronic ramp control helps keep test results
consistent as well as reduces
damage to sensitive products by providing a method to
gradually bring up the test
voltage and eliminate high voltage spikes. The dwell timer
also has a count down
feature so the operator can clearly see how much time is
left on a test.
9.PLC remote inputs and outputs.
The standard 9 pin interfaces provide outputs for Pass,
Fail, and Test in Process.
Inputs include Test, Reset and Program Select. This gives
the user all the basic
remotes required to configure the HypotPLUS II through
simple PLC relay control.
10. Front panel LCD displays test parameters and results.
A front panel LCD allows the operator to monitor the test.
The display holds the
results after a test item failure so that the operator can
easily review the test results.
Indications of short, breakdown, low fail, high fail, arc
fail and continuity failure are
clearly displayed.
11. Maximum output current 20 milliamps AC and 6 milliamps DC.
This makes this instrument a true hipot tester with enough
output current to test
capacitive loads in AC mode and allows the instrument to
comply with the UL 120ohm requirements.
12. Digitally controlled arc detection system.
Many tests require the monitoring of arcing levels even if
they do not exceed the
maximum trip current level. HypotPLUS II allows the operator
to select whether low
level arcs should be detected and provides the operator with
the ability to digitally
select and program multiple sensitivity levels. This makes
HypotPLUS II flexible
enough to test any product.
K
13.
Software calibration control.
HypotPLUS II is calibrated through the front panel keypad.
All calibration
information is stored in non-volatile memory. This allows
HypotPLUS II to be
completely calibrated without removing any covers and
exposing the technician to
hazardous voltages.
14. User selectable output voltage frequencies of 50 or 60
hertz.
HypotPLUS II was designed for the global market. This
feature makes it simple for
the user to select the output frequency in the AC hipot mode
so that products can be
tested at the same frequency they will be used at.
15. Output voltage fine adjustment.
To make HypotPLUS II usable in all types of applications,
the operator can
manually bring the voltage up or down in 10 volt increments
by simply pressing the
up and down arrow keys. This makes it very easy to adjust
the output voltage even
while HypotPLUS II is in the dwell mode so you can analyze
test results at different
voltages.
16. Built-in Continuity test mode.
HypotPLUS II meets ground continuity test requirements
called out by UL and other
safety agencies.
17. Flashing high voltage indicator.
A flashing LED located directly over the high voltage
terminal clearly indicates when
high voltage is active to provide maximum operator safety.
18. Easily configurable into an automated test system.
HypotPLUS II comes standard with rear output connectors and
rack mount handles
to make it simple to build into an automated system.
19. Comes complete with a test box for products terminated
in a line cord.
The standard US style receptacle box allows easy testing of
hipot and continuity on
line cord terminated products. As an additional benefit,
termination boxes are
available for testing products with line cords configured
for other countries.
Manual type:
Service and User Manual
Pages:
59
Size:
813.95 Kbytes (833485 Bytes)
Language:
english
Revision:
1.45
Manual-ID:
37545
Date:
2003 10 16
Quality:
Electronic document, no scan, very well readable.
Upload date:
2017 10 21
MD5:
ac2d03d48a85b6a707fd7339b1d42522
Downloads:
864
Information
SECTION I OPERATORS
MANUAL ...
1
SAFETY
...
2
INTRODUCTION
...
6
SPECIFICATIONS
...
11
WHAT S NEW
...
16
CONTROLS
...
18
INSTALLATION ...
23
QUICKSTART
...
26
OPERATION ...
29
OPTIONS
...
43
SECTION II SERVICE MANUAL
...
51
CALIBRATION ...
52
PARTS
LIST ...
54
SCHEMATICS
...
5
Comments