.....obsolete user manuals, a lot of repair manuals, free service manuals, rare schematic diagrams, usefull service instructions, pdf books, how to repair instructions, lost operating manuals, old handbooks, tons of part lists, hidden service bulletins, your instruction books, informative repair tips, complete disassembly routines.....


What are you looking for?


Keithley - 194A - Digital multimeter
Manufacturer:
Equipment:
194A
Date:
1985
Category:
Group:
Sub Group:

Information

FEATURES The Model 194A High Speed Voltmeter is a high speed DC voltage sampling instrument suitable for a wide variety of applications, including the analysis of laboratory phenomenon, as well as the characterization of transient and periodic waveforms. The Model 194A can sample at rates up to 1MHz with 2 1/2 digit, 8-bit usable resolution, or up to 100kHz with 4 1/2 digit, 16-bit resolution. Each A/D channel has 64K bytes of memory allowing up to 65,535 samples to be stored for later analysis with one of the many Model 194A mathematical functions. Key Model 194A features include: • Autoranging—Autoranging allows the instrument to measure a wide dynamic range of input signals. • Zero—A zero feature allows a baseline signal level to be subtracted from subsequent readings. The baseline can either be taken from an applied signal, or keyed in from the front panel or programmed over the IEEE-488 bus. • Filtering—Internal analog filtering with selectable poles of 50kHz or 500kHz is available to reduce the effects of noise. • Math Functions—A number of mathematical functions including average, integral, standard deviation, true RMS, peak, and peak-to-peak are included with the instrument software. • Dual-channel Operation—Two separate, isolated A/D channels are available with the optional Model 1944A A/D Module installed. • IEEE-488 Interface—A standard feature of the Model 194A that allows the instrument to be controlled from a computer. • Real Time Output—This port allows instrument data to be transmitted to a computer or similar device at the sampling rate via a user-supplied interface. • Programmable Sampling Rates—The instrument can be programmed to sample data as fast as 1MHz, or as slow as 1Hz. • Programmable Number of Samples—The number of samples per measurement sequence can be programmed to any value between 1 and 32,767 (16-bit resolution) or 1 and 65,535 (8-bit resolution). • Programmable Triggering—The instrument can be triggered from the input signal, an external trigger signal, from the other channel (when the Model 1944A option is installed), or over the IEEE-488 bus. Programmable triggering parameters include single or continuous modes, delay, slope, and level. • XY Mode—Allows the instrument to drive external display devices such as oscilloscopes and plotters. Internal software allows easy generation of graphs from sampled data. • Translator Mode—Simplifies IEEE-488 programming by allowing the use of English-like syntax. • External Sample Control—Allows sample collection to be synchronized to external events

show more

3 Manuals

Service and user manual
Manual type:
Service and user manual
Pages:
296
Size:
27.1 MB
Language:
english
Revision:
Manual-ID:
194A-901-01
Date:
January 1985
Quality:
Scanned document, all readable.
Upload date:
Aug. 21, 2018
MD5:
dec40fad-073c-d55e-3082-3f390d2a08de
Downloads:
564
User manual
Manual type:
User manual
Pages:
68
Size:
2.2 MB
Language:
english
Revision:
A
Manual-ID:
194A-903-01
Date:
January 1987
Quality:
Scanned document, all readable.
Upload date:
Aug. 21, 2018
MD5:
b027ed52-0b31-3320-366c-acd87271113e
Downloads:
342
User manual
Manual type:
User manual
Pages:
63
Size:
946.5 KB
Language:
english
Revision:
A
Manual-ID:
194A-900-01
Date:
January 1989
Quality:
Scanned document, all readable.
Upload date:
Aug. 23, 2018
MD5:
8e05bba8-9b30-c1f8-0118-467bb7f5ac73
Downloads:
865