.....obsolete user manuals, a lot of repair manuals, free service manuals, rare schematic diagrams, usefull service instructions, pdf books, how to repair instructions, lost operating manuals, old handbooks, tons of part lists, hidden service bulletins, your instruction books, informative repair tips, complete disassembly routines.....


What are you looking for?


Keithley - 2182 - Digital multimeter
Manufacturer:
Equipment:
2182
Date:
1998
Category:
Group:
Sub Group:

Information

The Model 2182 is a 7 1⁄2-digit high-performance digital nanovoltmeter. It has two input channels to measure voltage and temperature. The measurement capabilities of the Model 2182 are explained in Section 2 of this manual (see “Measurement overview”). Features of the Model 2182 Nanovoltmeter include: • Ratio — Provides comparison readings between two voltage inputs. Ratio performs V1/V2. • Delta — Provides average difference of Channel 1 inputs. Delta performs (V1t1–V1t2)/2. • Enhanced Delta, Pulse Delta, and Differential Conductance — The following tests can be performed when using a Model 2182/2182A with a Model 6220 or 6221 Current Source: — Delta - Uses a square wave output and a 3-point measurement algorithm to cancel the effects of thermal EMFs. — Pulse Delta (6221 and 2182A only) - Provides a pulse output and a 3-point (or 2-point) measurement algorithm for testing of temperature sensitive Device Under Test (DUT). — Differential Conductance - Uses a differential current output and a 3-point moving average algorithm to perform differential measurements. • mX+b and Percent — These calculations provide mathematical manipulation of readings. • Relative — Null offsets or establish baseline values. • Buffer — Store up to 1024 readings in the internal buffer. • Limits — Set high and low reading limits to test devices. • Internal Scanning — Scan the two input channels of the Model 2182. • External Scanning — Scan the channels or matrix points of Keithley Model 7001/7002 switching cards. • Setup Storage — Two instrument setups (user and factory defaults) can be saved and recalled. • Analog Output — With analog output gain set to one, a full range input will result in a 1V analog output. • Remote Interface — The Model 2182 can be controlled using the IEEE-488 interface (GPIB) or the RS-232 interface. • GPIB Programming Language — When using the GPIB, the instrument can be programmed using the SCPI or Model 182 (DDCs) programming language. • Closed-cover Calibration — The Model 2182 can be calibrated from either the front panel or the GPIB.

show more

2 Manuals

User manual
Manual type:
User manual
Pages:
339
Size:
2.0 MB
Language:
english
Revision:
B
Manual-ID:
2182A-900-01
Date:
May 2017
Quality:
Electronic document, no scan, very well readable.
Upload date:
Aug. 22, 2018
MD5:
fafdfed7-1d7a-8e85-ec9b-88b59893d53b
Downloads:
663
Service manual
Manual type:
Service manual
Pages:
114
Size:
1.2 MB
Language:
english
Revision:
C
Manual-ID:
2182-902-01 Rev. C
Date:
September 2001
Quality:
Electronic document, no scan, very well readable.
Upload date:
July 23, 2020
MD5:
9f150f6a-7f0c-40c3-c09b-30c63a51cdf3
Downloads:
159