.....obsolete user manuals, a lot of repair manuals, free service manuals, rare schematic diagrams, usefull service instructions, pdf books, how to repair instructions, lost operating manuals, old handbooks, tons of part lists, hidden service bulletins, your instruction books, informative repair tips, complete disassembly routines.....


What are you looking for?


Keithley - 6430 - Level Meter
Manufacturer:
Equipment:
6430
Date:
2001
Category:
Group:
Sub Group:

Information

Product overview The SourceMeter combines a precise, low-noise, highly stable DC power supply with a lownoise, highly repeatable, high-impedance multimeter and a remote preamplifier for ultra low current measurements. It has 0.012% basic accuracy with 5 1⁄2-digit resolution. At 5 1⁄2 digits, the SourceMeter delivers 520 readings/second over the IEEE-488 bus. At 4 1⁄2 digits, it can read up to 2000 readings/second into its internal buffer. The unit has broad source and measurement ranges: Source voltage from 5μV to 210V; measure voltage from 1μV to 211V. Source current from 0.5fA to 105mA; measure current from 10aA to 105.5mA. Measure resistance from 100μΩ (<100μΩ in manual ohms) to 21.1TΩ. Maximum source power is 2.2W. NOTE The Model 6430 is Y2K compliant. Some additional capabilities of the SourceMeter include: Perform measurements at the DUT using the small Remote PreAmp. Concurrent measurements of all three functions over the remote interface. Source-measure sweep capabilities (linear and logarithmic staircase sweeps, source sweep list of up to 1000 points, memory sweep of up to 100 instrument setups). 6-wire ohms measurement with programmable I-source or V-source with V or I clamp. 2.2W, 4-quadrant source and sink operation. Up to 11 stages of limit testing with a built-in comparator for pass/fail testing. Digital I/O for stand-alone binning operations or interface to component handler. Programming language and remote interfaces — The SourceMeter uses the SCPI programming language and two remote interface ports (IEEE-488/GPIB and RS-232C). Trigger-Link interface to Keithley Series 7000 switching hardware. Math expressions — 5 built-in, up to 5 user-defined (bus only). Reading and setup storage — Up to 2500 readings and seven setups (five user defaults, factory default, *RST default) can be stored and recalled. Closed-cover calibration — The instrument can be calibrated either from the front panel or remote interface.

show more

1 Manual

User manual
Manual type:
User manual
Pages:
558
Size:
2.3 MB
Language:
english
Revision:
D
Manual-ID:
6430-901-01
Date:
June 2001
Quality:
Electronic document, no scan, very well readable.
Upload date:
Aug. 22, 2018
MD5:
6a7ce5c7-365a-6af2-50e6-ac1dac40be72
Downloads:
356