INTRODUCTION
The Wavetek Modeis 3003 through 3006 are rugged, completely
solid-state Signal Generators covering the frequency range
of .001 or 1 to 520 MHz. Models 3004 and 3006 cover the
range of .001 to 520 MHz while Modeis 3003 and 3005 cover
the 1 to 520 MHz range. Modeis 3005 and 3006 offer 100 Hz
resolution while on Models 3003 and 3004 the resolution is 1
kHz. The output can be amplitude or frequency modulated and
the level can be set between +13 and -137 dBm.
1.1.1 FREQUENCY CHARACTERISTICS
The frequency of the instrument is set via 6 or 7
front-panel Lever/Indicator switches which yield a
resolution of 1 kHz or 100 Hz. In addition, remote
programmers are available to facilitate semi-automatic
programming of frequency and GPiB programming of both
frequency and output level.
The accuracy of the instrument is based on a
crystal-controlled oscillator that serves as a stable
frequency reference that enables the instrument to provide
high-stability signals to an accuracy of 0.001% over its
specified frequency range. This accuracy includes possible
errors due to short-term drift, long-term drift, incidental
FM, and variations due to line voltage changes and
temperature changes. With the FREQUENCY VERNIER out of the
CAL position, the frequency is accurate to 0.001% ±10 k Hz.
The accuracy of the instrument can be Improved by using
either the optional External Reference input, or the
optional High Stability internal Reference. An Auxiliary
RF output option is also available to drive a counter. Refer
to Section 1.3 for a listing of options available for each
instrument.
1.1.2 MODULATION
These instruments also feature both internal and external AM
and FM capabilities. The internal and external sources can
operate independently, or may be used simultaneously to
produce complex modulation.
Internal modulation frequencies include 400 Hz, 1000 Hz, and
two preset frequencies between 100 Hz and 10 kHz, selected
by the user.
Modulation is indicated on a front-panel meter calibrated
for full-scale readings of 30% and 100% AM, and 3, 10, 30,
and 100 kHz deviation for FM operation.
1.1.3 OUTPUT LEVEL FEATURES
The output power is indicated on a front-panel meter
calibrated in both dBm and VRMS, A fifteen-position, 10 dB/
step Attenuator used in conjunction with an 11 dB VERNIER
control provides the user with a range of +13 dBm to -137
dBm. A Programmable Attenuator option is available covering
the range of from 0 to 109.9 dB attenuation in .1 dB steps
with +13 dBm as the 0 dB reference level.
The calibrated output of the Instrument is leveled to within
±0.75 dB across the complete frequency range of the instrument.
Reverse power protection is also available as an option.
2 Manuals
Service and user manual
Manual type:
Service and user manual
Pages:
236
Size:
12.9 MB
Language:
english
Revision:
E
Manual-ID:
6510-00-0024
Date:
Quality:
Scanned document, reading partly badly, partly not readable.
Upload date:
Nov. 6, 2011
MD5:
09f1468d-084b-43d5-2520-89e667a3e1f3
Downloads:
3187
User manual
Manual type:
User manual
Pages:
66
Size:
2.5 MB
Language:
english
Revision:
Manual-ID:
Date:
Quality:
Scanned document, reading partly badly, partly not readable.
Upload date:
Aug. 13, 2018
MD5:
91a50ae9-0da3-121e-3595-a6860e47b717
Downloads:
2086