Icom - FP-561 - Plotter
Manufacturer:
Image 1 of 5
If you have any other photos or manuals for the
Icom FP-561
you can
upload the files here.
Equipment:
FP-561
Date:
1999
Category:
Group:
Sub Group:
Information
FP-561
‘ GENERAL
• Display : 5.6 inch TFT color LCD (320×234 pixels)
• Power supply requirement : 11–30 V DC
• LCD brightness : 16 levels
• Power consumption : Less than 22 W (Less than 1.8 A at 12 V DC)
• Dimensions (projections not included) : 186(W)×203(H)×102(D) mm; 75⁄16(W)×8(H)×4(D) in
• Weight (approx.) : 2.2 kg; 4 lb 14 oz
• Usable temperature range : 0°C to +50°C; +32°F to +122°F
• Unit of water depth : m (meter), FT (feet), FM (fathom)
• Unit of water temperature : °C, °F
• Unit of speed : KT (knots), km/h, MI/h (miles/h)
• Unit of distance : NM (nautical miles), km, MI (miles)
• Input data format : NMEA0183, Water temp./speed, DGPS
• Output data format : NMEA0183 (GGA, GLL, XTE, AAM, VTG, BOD, WPL, BWC),
Start-stop serial forward; 4800 bps
‘ GPS
• Receive system : 12 parallel-channel, all-in-one view
• Receive frequency : 1575.42 MHz (±1 MHz)
• Measuring accuracy (2DRMS) : Position 100 m, 95% of the time, PDOP≤3 (Less than 100 m, S/A OFF)
Speed Less than 1 m/sec. (PDOP≤3, S/A ON)
NOTE: All GPS receivers are subject to degradation of position and velocity accuracy under the U.S. Department of
Defence.
• Data renewed interval : 1 sec.
‘ PLOTTER
• Scale setting : 16 steps
• Plotting interval : 5 sec. to 60 min., 0.01–9.99 NM*
• No. of track memories : 5000 (selectable from 7 colors)
• No. of route memories : 20 (50 points/route)
• No. of event markers : 500
• Navigation computer : Vessel position (longitude/latitude), cursor position, distance, elapsed time,
course-out distance, direction, distance, time
• Data indication : Coastline, place name, contour line, route, lighthouse, longitude/latitude line
• Alarm : Area and Arrival alarms
VIDEO SOUNDER
• Transmission freq. : 50 kHz, 200 kHz
• Output power : 500 W RMS
• Water depth range : 5–640 m* in 8-color indication
• Water temp. range : 0°C to +40°C; +32°F to +104°F
• Speed range : 0.0–99.9 KT*
• Bottom lock expansion range : 5 m*, 10 m*, 20 m*, 40 m*
• Phase shift variable range : 1–640 m*
• Type of display screen : Standard, A-scope, dual frequencies, bottom and marker zoom
• Picture sweep speed : 6 levels including pause
• Alarm : Shallow, depth and fish school
*selectable in each unit
1 Manual
Service manual
Manual type:
Service manual
Pages:
48
Size:
2.8 MB
Language:
english
Revision:
Manual-ID:
S-13602II-CD
Date:
Quality:
Electronic document, no scan, very well readable.
Upload date:
June 17, 2012
MD5:
8d256c72-15e6-442e-7df7-34bb5105d903
Downloads:
1345