.....obsolete user manuals, a lot of repair manuals, free service manuals, rare schematic diagrams, usefull service instructions, pdf books, how to repair instructions, lost operating manuals, old handbooks, tons of part lists, hidden service bulletins, your instruction books, informative repair tips, complete disassembly routines.....


What are you looking for?

extended search


Vishay Instruments BAM-1 Level Meter
Manufacturer:
Model:
BAM-1
Date:
1976
Class:
Type:
SubType:
Bridge Amplifier and Meter

Information

The BAM-1 Bridge Amplifier and Meter is a battery- operated instrument used primarily to measure the -output of resistance-type strain gages or transducers. Static outputs can be read directly on the self-contained deflection meter or an external recorder; dynamic outputs up to 20 kHz can be read on an Oscilloscope. . Briefly, the BAM-1 consists of: a) A battery to supply bridge excitation up to 12 Vdc; b) Bridge completion and circuits to achieve initial bridge balance; c) Shunt-calibration circuits; d) A fixed-gain dc differential Amplifier (with battery power); and e) A linear 4½" center-zero readout meter. 1.2 The principle features of the BAM-1 include: ... Operation by self-contained batteries (115 and 230 Vac Power Packs optional). ... Ultra-stable dc Amplifier with a gain of 250, flat up to 20 kHz (100 kHz in Model BAM-1B). ... Adjustable system gain from ± 100 to 15,000 µe full scale (one active 120Ω gage). ... Built-in shunt calibration from 20 to 20,000µe in 10 steps (one active gage). ... Amplifier can be used independently for thermo couples, etc.

show more

Service and User Manual
Manual type:
Service and User Manual
Pages:
12
Size:
674.53 Kbytes (690714 Bytes)
Language:
english
Revision:
Manual-ID:
Date:
unknown
Quality:
Scanned document, all readable.
Upload date:
2013 04 01
MD5:
6eaf71fac6dcfde622eef2beeed6dca8
Downloads:
666

Information

This Manual applies specifically to BAM-l's above serial number 14600. The Operating Procedure applies to essentially all BAM-1 "s including those made by Vishay Instruments or Ellis Associates, regardless of date of manufacture, except for Quarter Bridge hook-up and other very minor discrepancies. SECTION 1 : DESCRIPTION Page GENERAL ... 3 SPECIFICATIONS ... 3 CONTROLS ... 4 SECTION 2: OPERATING PROCEDURE INPUT CONNECTIONS ... 5 WIRING CONSIDERATIONS ... 5 INITIAL ADJUSTMENTS ... 6 CALIBRATION CALCULATIONS ... 6 STATIC MEASUREMENTS WITH PANEL METER ... 7 DYNAMIC MEASUREMENTS ... ... 8 NOISE ... 9 WARRANTY ... 10 SECTION 3: SERVICING DATA BATTERY REPLACEMENT ... 11 TROUBLE SHOOTING GUIDES ... II ADJUSTMENTS ... 11 COMPONENT REPLACEMENT ... 11 SCHEMATIC ... 1 ... 12

show more

Add Comment

* Required information

Comments

No comments yet. Be the first!