Adret Electronique 3100 B Generator
Manufacturer:
Model:
3100 B
Date:
1979
Class:
Type:
SubType:
Frequency Synthesizer
Information
The 3100B ADRET
Synthesizer is a digitally controlled signal
Generator which delivers all 0.01 Hz to 200 kHz frequencies
with 0.01 Hz resolution.
The synthesized frequency can be either manually dialled
through eight rotary switches on the front panel of the
instrument (Local mode), or programmed in parallel BCD code
through TTL signals sent to the programming connector on the
rear panel of the instrument (Remote mode).
Two channels A and B simultaneously deliver two output
signals in phase quadrature with 5 n or 50 a impedance and
an electromotive force adjustable from 0 to 10 Vpeak.
Moreover, the signal delivered by channel A can have the
following forms : sine wave, positivd square wave,
symmetrical square wave, negative square wave, TTL level
square wave.
According to the user's needs, the 3100B
Generator
Synthesizer can be fitted with the following options :
- Option 311IB : progranmable attenuator
This option allows to attenuate one of the output signals of
the
Generator Synthesizer from 0 dB to 79.9 dB with 0.1 dB
resolution. The attenuation value can be either manually
dialled through three rotary switches in Local mode, or
programmed in parallel BCD code through TTL signals in
Remote mode.
- Option 3112B : programmable phase-shifter
This option delivers a sinusoidal signal phase-shifted from
0° to 359.9° with regard to the signal of channel A of the
3100B
Generator Synthesizer. The phase-shift value can be
either manually dialled through four thumble wheel switches
in Local mode, or programmed in parallel BCD code through
TTL signals in Remote mode. The electromotive force of the
phase-shifted signal is adjustable from 0 to 10 Vpeak with 5
ft or 50 ft output impedance.
- Option 3114B : Search and Sweep
This option allows progressive frequency variation of the
Generator Synthesizer output signals. Four modes of
operation are possible depending on the function required :
- Search function
- Free-run Sweep
- Triggered Sweep
- Search or Sweep by external signal
In all cases, twenty-one "birdy" or rectified markers
display the frequency variation achieved.
Manual type:
User Manual
Pages:
53
Size:
1.27 Mbytes (1335633 Bytes)
Language:
english
Revision:
Manual-ID:
Date:
unknown
Quality:
Scanned document, all readable.
Upload date:
2014 04 20
MD5:
49cba052db962f96b7eaf41408dcc517
Downloads:
796
Information
CHAPTER I FUNCTIONAL DESCRIPTION
CHAPTER I I SPECIFICATIONS
I I - l SPECIFICATIONS OF
Synthesizer 3 » B I I - I
I I -2 SPECIFICATIONS OF OPTION 3111B I I - 4
11-3 SPECIFICATIONS OF OPTION 3112B H -5
I I-4 SPECIFICATIONS OF OPTION 3114B I I - 6
CHAPTER I I I PRINCIPLE OF OPERATION
I I I - l
Generator Synthesizer 3100B H I - 1
I I I -2 OPTION 3111B H I-1
111-3 OPTION 3112B H I-2
I I I -4 OPTION 3114B H I-2
CHAPTER IV PRELIMINARY INSTRUCTIONS
IV-1 AC LINE CONNECTION IV-1
IV-2 MOUNTING IN 19" RACK IV -1
CHAPTER V OPERATING INSTRUCTIONS
V-l EXTERNAL DESCRIPTION V-l
V-2 3100B OPERATING INSTRUCTIONS V-l
V-2-1 Switching on V-l
V-2-2 Local Mode V-l
V-2-3 Remote Mode V-2
V-2-4 Output signals V-3
V-2-5 Reference frequency V-4
V-2-6 Supply voltages output V-5
V-3 3111B OPERATING INSTRUCTIONS V-6
V-3-1 Local Mode V-6
V-3-2 Remote Mode V-6
V-4 3112B OPERATING INSTRUCTIONS V-7
V-4-1 Local Mode V-7
V-4-2 Remote Mode V-8
V-4-3 Output signal V-8
V-5 3114B OPERATING INSTRUCTIONS V-9
V-5-1 Search function V-9
V-5-2 Free-run mode V-10
V-5-3 Triggered mode v-12
V-5-4 External mode v-1
CHAPTER VI CIRCUIT DESCRIPTION
VI-1 INTRODUCTION VI-1
VI-2 CENTADE VI-2
VI-3 STANDARD DECADE VI-5
VI-4 TWENTY-INCREMENT UNIT VI-7
VI-5 OUTPUT MIXER VI-10
VI-6 FUNCTION SWITCH VI-11
VI-7 OUTPUT
Amplifier VI-11
VI-8 TIME BASE VI-11
VI-9 PROGRAMMABLE ATTENUATOR OPTION 3111B VI-12
VI-10 PROGRAMMABLE PHASE-SHIFTER OPTION 3112B VI-13
VI-10-1 Digital Phase-Shift VI-14
VI-10-2 Generation sin <t> / cos <p VI-14
VI-10-3 Output Circu it VI-15
V I-U SEARCH AND SWEEP OPTION 3114B VI-15
VI-11-1 Sweep VI-16
V I-11-2 Interpolation VI-16
OPTION IEEE BUS OPERATING INSTRUCTIONS V I -1 8
CHAPTER VII MAINTENANCE
CHAPTER V III PLATES, SCHEMATICS, PARTS LIST
Manual type:
Service Manual
Pages:
144
Size:
4.33 Mbytes (4543063 Bytes)
Language:
english
Revision:
Manual-ID:
Date:
unknown
Quality:
Scanned document, all readable.
Upload date:
2014 04 20
MD5:
c712f94cbb53ba5cc8758c4a8f13df77
Downloads:
1229
Information
MEANING of the part number and Adret codes
ARTICULATION and BLOCK DIAGRAM
DIAGRAMS and NOMENCLATURES
COMPONENTS LIST
RECOMMENDED SUB-ASSEMBLIES or PC board
- Extended boards
- Set of 100% of repairs
- Set of 70% or repairs
- Set of components
Warranty and Assistance
Manual type:
Service Manual
Pages:
26
Size:
687.51 Kbytes (704007 Bytes)
Language:
english
Revision:
Manual-ID:
Date:
unknown
Quality:
Scanned document, all readable.
Upload date:
2014 04 20
MD5:
60a25f1d094b1b1e112695f0a126d28a
Downloads:
975
Manual type:
User Manual
Pages:
59
Size:
2.02 Mbytes (2116967 Bytes)
Language:
french
Revision:
2
Manual-ID:
Date:
1978 12 01
Quality:
Scanned document, all readable.
Upload date:
2020 05 09
MD5:
0f2701adaffa0736d522abc131e85b36
Downloads:
234
Information
CHAPITRE I DESIGNATION FONCTIONNELLE DE L'APPAREIL
CHAPITRE II CARACTERISTIQUES TECHNIQUES
II-1 Caractéristiques du synthétiseur 3100B II-l
11-2 Caractéristiques de l'option 3111B II-4
11-3 Caractéristiques de l'option 3112B 11-5
II-4 Caractéristiques de l'option 3114B 11-6
CHAPITRE III PRINCIP.E DE FONCTIONNEMENT
III-l Générateur synthétiseur 3100B III-l 111-2 Option 3111B III-l 111—3 Option 3112B 111-2
III-4 Option 3114B 111-2
CHAPITRE IV INSTRUCTIONS PRELIMINAIRES
IV-1 Mise en service IV-1
IV-2 Montage en rack 19" IV-1
CHAPITRE V INSTRUCTIONS POUR L'UTILISATION
V-l Description des organes de commande V-rl
V-2 Utilisation du 3100B V-l
V-2-1 Mise en oeuvre V-l
V-2-2 Mode Local V-l
V-2-3 Mode Distance V-2
V-2-4 Signaux de sortie V-3
V-2-5 Fréquence de référence V-5
V-2-6 Sortie tensions d'alimentation V-6
V-3 Utilisation de l'option 3111B V-6
V-3-1 Mode Local V-6
V-3-2 Mode Distance V-7
V-4 Utilisation de l'option 3112B V-7
V-4-1 Mode Local V-8
V-4-2 Mode Distance V-8
V-4-3 Signal de sortie V-8
V-5 Utilisation de l'option 3114B V-9
V-5-1 Interpolation manuelle V-9
V-5-2 Mode Relaxé V-ll
V-5-3 Mode Déclenché V-13
V-5-4 Mode Extérieur
CHAPITRE VI DESCRIPTION DES CIRCUITS
VI-1 Introduction VI-1
VI-2 Centade VI-2
VI-3 Décade Standard VI-5
VI-4 Vingtade VI-8
VI-5 Mélangeur de Sortie • VI-10
VI-6 Commutateur de Fonctions VI-11
VI-7 Amplificateur de Sortie VI-12
VI-8 Base de Temps VI-12
V1-9 Option Atténuateur Programmable 3111B VI-12
VI-10 Option Déphaseur Programmable 3112B VI-13
VI-10-1 Déphasage Numérique VI-14
V1-10-2 Génération sin ij>/cos $ VI-13
VI-10-3 Circuit de Sortie VI-15
VI-11 Option Interpolation et Wobulation 3114B V1-16
VI-11-1 Balayage VI-17
VI-11-2 Interpolation VI-17
CHAPITRE VII MAINTENANCE
PLANCHES HORS-TEXTE, SCHEMAS ELECTRIQUES, NOMENCLATURES
Comments