The 8860A is a fully-guarded, microprocessor-controlled,
5-1/2 digit, five-function digital multimeter designed for
bench-top applications. Its measurement functions include:
VDC, true RMS VAC (ac coupled), true RMS VAC (decoupled),
two-terminal ohms, and four-terminal ohms. Each voltage
function is .provided with five ranges. Six ranges are
available for each of the ohms functions. The ranges can be
selected automatically (autorange) or manually.
Several other performance features are provided with the
8860A. They include:
• Total push-button control
• Dual slope a/d conversion
• Push-button zero for V dc and ohms
• Selectable sample rate and resolution (4-1/2 or 5-1/2 digits)
• Selectable internal/external guard connection
• Selectable trigger mode: auto, manual, external
• Three math functions: offset, limits and peak-to-peak.
• Numeric data entry push-buttons for use in loading the
constants for the offset, limits, and peak-to-peak functions.
• A 5-1/2 digit measurement display (mantissa) field with
sign and floating decimal point.
• A two-digit exponent field with sign for displaying
exponents of 10 and high, low, pass (H,L,P) limits
information. Exponents are automatically displayed for
recalled^data.
• Measurement units annunciators that operate in conjunction
with the display decimal point to display the selected range.
• Overload protection for all functions and ranges.
• Selectable local/remote operation.
The 8860A is housed in a plastic Portable Test Instrument
(PT1) case. The case includes a retractable carrying handle
and a fold-down bail. When extended, the bail provides a
convenient tilt for bench-top operation. The PT1 design
allows the 8860A to be stacked and latched with other
instruments in the Fluke PT1 product line. Stacking saves
bench space and allows the instruments in the stack to be
moved as a single unit.
Operating power for the 8860A is selectable for the
following configurations: 100, 120,220, or 240V ac ±10%; 50
or 60 Hz. The unit is shipped in the configuration specified
at the time of purchase. Since the voltages are selectable,
they can be reset in the field by a qualified technician.
(Instructions for line voltage selection are given in the
Calibration manual.)
1 Manual
User manual
Manual type:
User manual
Pages:
64
Size:
1.8 MB
Language:
english
Revision:
Manual-ID:
541268
Date:
April 1980
Quality:
Scanned document, reading partly badly, partly not readable.
Upload date:
Jan. 15, 2018
MD5:
723f051c-36dd-cc8a-c8bd-315ccc17aab8
Downloads:
607