.....obsolete user manuals, a lot of repair manuals, free service manuals, rare schematic diagrams, usefull service instructions, pdf books, how to repair instructions, lost operating manuals, old handbooks, tons of part lists, hidden service bulletins, your instruction books, informative repair tips, complete disassembly routines.....


What are you looking for?

extended search


Genevri OGB Polycare 2 Incubator
Manufacturer:
Model:
OGB Polycare 2
Date:
2009
Class:
Type:
SubType:

Information

The philosophy that has guided GINEVRI in the design of their products for the last 40 years is Maximum Performance, and User Friendliness at the same time. This philosophy has conducted to the line of incubators OGB Poly Care. Poly care control units are microprocessor driven and can control all the parameters necessary to obtain the ideal environment for the premature baby. Depending on the model is possible to monitor and control: • Temperature (Air, Skin) with proportional heating; • Humidity, with an integrated sterile humidity generating system; • Oxygen concentration in the hood or in the head-box; Data are displayed on big, clear colour displays and the desired parameter values are set trough soft-touch sealed keys arranged in an intuitive and error-free pattern. The intensive care incubators can be equipped with the revolutionary Hot-Spot radiant heater, when this system is fitted the baby skin temperature is maintained constant even with both doors open, thus eliminating the clumsiness of the double wall and the danger of the air curtain. Technology and materials The choice of materials and technologies employed is what makes the difference in the new generation of incubators. Hood, base and main components of the Poly Care incubators are injection-moulded in Polycarbonate (Lexan). Poly Care incubators are «unique» for their design, features and manufacturing technologies, on the market it is impossible to find apparatus with all this features at the same time. The injection-moulding in a single block , the absence of glued junctions and the round shapes improve the air circulation, reduce the internal noise level and allow a radical cleaning and sterilisation. All this features and details guarantee the Incubator optimal performance. To order a spare part from every part of the world what you need is just a fax and a part number. The technical solutions employed for the Poly Care incubators make maintenance and servicing easy and economical. Even the need for specialised service engineers is no longer required. This happens because the mechanical components, manufactured with a moulding process, are all strictly identical and because, thanks to digital electronics, servicing means only changing a board or a probe. Incubator base, control panel, humidifier, patient tray and Smooth-Tilt, are all injection moulded in Polycarbonate (Lexan). Polycarbonate is unbreakable, high temperature resistant, fire retardant, disinfectants and chemicals resistant. Thanks to the materials and the technologies employed the apparatus can be completely disassembled without tools in a few minutes. The hood of Poly Care incubators is made in lexan too, this material is, unbreakable, heat resistant (up to 150°C), durable. The single piece injection moulding and, therefore, the absence of joined or glued parts, guarantees hygiene and sterility. For all this reasons Lexan hoods outperform under every aspect traditional acrylic plexiglas hoods. For an optimal access to the patient the doors on the two sides of the hood can be completely opened and when open, the hood top is still accessible. The hood is equipped with six port-holes provided of dampened opening.

show more

User Manual
Manual type:
User Manual
Pages:
33
Size:
1.90 Mbytes (1991343 Bytes)
Language:
english
Revision:
Manual-ID:
Date:
01 November 2009
Quality:
Electronic document, no scan, very well readable.
Upload date:
10 February 2018
MD5:
9505270a9dd745019f1fb1f871370b54
Downloads:
288

Information

1 PRESENTATION ... 5 2 “EC” CERTIFICATE ... 6 3.1-OPERATING PRECAUTIONS ... 7 3.2 ELECTRICAL PRECAUTIONS ... 8 3.3 EXPLOSION PRECAUTIONS ... 8 4. INTRODUCTION ... 9 5. GENERAL INSTRUCTIONS ... 11 5.1 GENERAL DESCRIPTIONS ... 11 5.2 CNTROL PANEL ... 12 5.3 UNPACKING ... 14 5.4 INCUBATORS ASSEMBLY ... 14 5.4.1 Base ... 14 5.4.2 Hood ... 15 5.4.3. Micro-Filter ... 16 5.4.4. Control Panel ... 16 5.4.5 Radiant Heater Hot Spot ... 17 6 - OPERATION ... 18 6.1 OPERATING INSTRUCTIONS ... 18 6.2 OPERATION MODES ... 19 6.2.1 Air Temperature Control ... 19 6.2.2 Skin Temperature Control ... 20 6.3 ALARM DEVICES ... 20 6.3.1 Power Failure Alarm ... 20 6.3.2 Fan Block Alarm ... 20 6.4 HOOD ASSEMBLY ... 21 6.5 BASE ... 21 6.6 AIR CIRCULATING SYSTEM ... 22 6.7 OXYGEN CONCENTRATION CONTROL ... 22 6.7.1 Oxygen Concentration Table ... 23 6.7.2 Oxygen Concentration Table ... 23 6.8 HUMIDITY SYSTEM ... 23 7 ACCESSORIES ... 25 8 - OPTIONALS ... 27 8.1 TROLLEYS (OPTIONAL) ... 27 9 SPARE PARTS ... 28 10 ROUTINE MAINTENANCE ... 29 10.1. MICROFILTER ... 29 10.2 CLEANING AND STERILISATION ... 29 10.3 DISASSEMBLY ... 29 10.4 DUSTING ... 29 10.5 WASHING ... 29 10.6 DRYING ... 29 10.7 HEATING UNIT ... 30 11 - TROUBLESHOOTING ... 30 12 - TECHNICAL DATA SHEET ... 31 13. OGB POLY CARE 2 COMPLIES WITH THE FOLLOWING REGULATIONS: ... 32 14. ECO-COMPATIBLE RECALL AND DISPOSAL ... 32

show more

Service Manual
Manual type:
Service Manual
Pages:
30
Size:
1.91 Mbytes (2004633 Bytes)
Language:
english
Revision:
Manual-ID:
Date:
01 November 2009
Quality:
Electronic document, no scan, very well readable.
Upload date:
10 February 2018
MD5:
9bcc153370bac24039901904310d0188
Downloads:
290

Information

1 PRESENTATION ... 4 2 “EC” CERTIFICATE ... 5 3 CALIBRATION CHECK ... 6 3.1 TEMPERATURE PROBES CALIBRATION ... 6 4. ELECTRICAL INTERCONNECTION DIAGRAM ... 8 5. SPARE PART ... 10 5.1 Incubator POLY CARE 2 ... 10 5.2 LOCKED POWER CONTROL PANEL ... 12 5.3 ASSEMBLED BODY INCUBATOR ... 14 5.4 ASSEMBLED WATER BOX ... 16 5.5 ASSEMBLED CONTROL PANEL ... 18 5.6 ASSEMBLED HOOD ... 20 5.7 ASSEMBLED BASAMENT ... 21 5.8 CONTROL PANEL LOCKED KEYBOARD ... 23 5.9 ASSEMBLED WOOD DOOR ... 25 6. MAINTENANCE SERVICE ... 26 7. PROGRAMMED AND PREVENTIVE MAINTENANCE ... 27 8. FINAL CHECK ... 28 9. TECHNICAL DATA ... 29 10. OGB POLY CARE 2 COMPLIES WITH THE FOLLOWING STANDARDS: ... 30