Keithley - 182 - Digital multimeter
Manufacturer:
Image 1 of 1
If you have any other photos or manuals for the
Keithley 182
you can
upload the files here.
Equipment:
182
Date:
1993
Category:
Group:
Sub Group:
Information
FEATURES
The Model 182 Sensitive Digital Voltmeter is a
fully-programmable instrument with 1nV sensitivity. The
Model 182 provides highly-accurate, stable, low-noise
readings on five ranges for DC voltage measurements between
1nV and 30V.
» Special input characteristics: Low common-mode current and
RFI for minimal undesirable effects on sensitive circuits.
Fast open input recovery places the input preamp in a
nonsaturating state when the inputs are open while the
instrument is in the one-shot mode.
• High-sensitivity, low-noise measurements: The Model 182
has a resolution of 1nV on the 3mV range at 6 1/2-digit
resolution with only 15nV of noise.
• Selectable integration periods: Choice of 3msec, line
cycle, and 100msec integration periods allows the best
compromise between measurement speed, resolution, and noise.
• Standard IEEE-488 interface: The built-in IEEE-488
interface allows the instrument to communicate with and be
controlled from a computer.
• 1,024 Reading Buffer: The 1,024-reading buffer can be
programmed and data can be recalled from the front panel or
over the IEEE-488 bus. The buffer can be programmed to store
from 1 to 1,024 readings or on a continuous basis. Mean,
maximum, minimum, and standard deviation values are also
available.
- Analog output: The analog output, which supplies a 3V full
scale analog of the measurement at the reading rate, is
available on the rear panel. User-programmable gain and
relative features for optimized use of external analog
recording devices such as chart recorders.
• Digital filter: The 3-pole digital filter can be used to
minimize reading noise. Filter response can be tailored for
the best compromise between speed and noise reduction.
• Reading Relative: The relative feature can be used to null
offsets to optimize measurement accuracy, or to store and
subtract a baseline value from subsequent readings.
• Digital calibration: Allows easy calibration of instrument
voltage measurements and the analog output without having to
remove the top cover.
5 Manuals
Service and user manual
Manual type:
Service and user manual
Pages:
225
Size:
18.4 MB
Language:
english
Revision:
Fifth Printing
Manual-ID:
182-901-01
Date:
Quality:
Scanned document, all readable.
Upload date:
May 20, 2012
MD5:
a0e09562-ee9c-6197-0021-28e426d49a1d
Downloads:
3366
Service and user manual supplement
Manual type:
Service and user manual supplement
Pages:
1
Size:
43.1 KB
Language:
english
Revision:
Manual-ID:
182-901-02E
Date:
Quality:
Scanned document, all readable.
Upload date:
May 20, 2012
MD5:
63b3ce77-a0f9-b925-f455-0f265d5de0fa
Downloads:
766
User manual
Manual type:
User manual
Pages:
38
Size:
194.9 KB
Language:
english
Revision:
B
Manual-ID:
182-903-01
Date:
Quality:
Electronic document, no scan, very well readable.
Upload date:
March 2, 2014
MD5:
13412930-932d-7970-f19b-73435526f17c
Downloads:
671
Datasheet
Manual type:
Datasheet
Pages:
1
Size:
80.1 KB
Language:
english
Revision:
Manual-ID:
Date:
Quality:
Scanned document, all readable.
Upload date:
March 7, 2014
MD5:
b74920da-bc0b-35a6-df62-c2274118643e
Downloads:
564
User manual
Manual type:
User manual
Pages:
142
Size:
5.7 MB
Language:
english
Revision:
A
Manual-ID:
182-901-01
Date:
October 1990
Quality:
Scanned document, all readable.
Upload date:
Aug. 21, 2018
MD5:
77c2cb1f-3fe2-4e71-7afc-39693528677f
Downloads:
688