.....obsolete user manuals, a lot of repair manuals, free service manuals, rare schematic diagrams, usefull service instructions, pdf books, how to repair instructions, lost operating manuals, old handbooks, tons of part lists, hidden service bulletins, your instruction books, informative repair tips, complete disassembly routines.....


What are you looking for?


Keithley - 182 - Digital multimeter
Manufacturer:
Equipment:
182
Date:
1993
Category:
Group:
Sub Group:

Information

FEATURES The Model 182 Sensitive Digital Voltmeter is a fully-programmable instrument with 1nV sensitivity. The Model 182 provides highly-accurate, stable, low-noise readings on five ranges for DC voltage measurements between 1nV and 30V. » Special input characteristics: Low common-mode current and RFI for minimal undesirable effects on sensitive circuits. Fast open input recovery places the input preamp in a nonsaturating state when the inputs are open while the instrument is in the one-shot mode. • High-sensitivity, low-noise measurements: The Model 182 has a resolution of 1nV on the 3mV range at 6 1/2-digit resolution with only 15nV of noise. • Selectable integration periods: Choice of 3msec, line cycle, and 100msec integration periods allows the best compromise between measurement speed, resolution, and noise. • Standard IEEE-488 interface: The built-in IEEE-488 interface allows the instrument to communicate with and be controlled from a computer. • 1,024 Reading Buffer: The 1,024-reading buffer can be programmed and data can be recalled from the front panel or over the IEEE-488 bus. The buffer can be programmed to store from 1 to 1,024 readings or on a continuous basis. Mean, maximum, minimum, and standard deviation values are also available. - Analog output: The analog output, which supplies a 3V full scale analog of the measurement at the reading rate, is available on the rear panel. User-programmable gain and relative features for optimized use of external analog recording devices such as chart recorders. • Digital filter: The 3-pole digital filter can be used to minimize reading noise. Filter response can be tailored for the best compromise between speed and noise reduction. • Reading Relative: The relative feature can be used to null offsets to optimize measurement accuracy, or to store and subtract a baseline value from subsequent readings. • Digital calibration: Allows easy calibration of instrument voltage measurements and the analog output without having to remove the top cover.

show more

5 Manuals

Service and user manual
Manual type:
Service and user manual
Pages:
225
Size:
18.4 MB
Language:
english
Revision:
Fifth Printing
Manual-ID:
182-901-01
Date:
Quality:
Scanned document, all readable.
Upload date:
May 20, 2012
MD5:
a0e09562-ee9c-6197-0021-28e426d49a1d
Downloads:
3366
Service and user manual supplement
Manual type:
Service and user manual supplement
Pages:
1
Size:
43.1 KB
Language:
english
Revision:
Manual-ID:
182-901-02E
Date:
Quality:
Scanned document, all readable.
Upload date:
May 20, 2012
MD5:
63b3ce77-a0f9-b925-f455-0f265d5de0fa
Downloads:
766
User manual
Manual type:
User manual
Pages:
38
Size:
194.9 KB
Language:
english
Revision:
B
Manual-ID:
182-903-01
Date:
Quality:
Electronic document, no scan, very well readable.
Upload date:
March 2, 2014
MD5:
13412930-932d-7970-f19b-73435526f17c
Downloads:
671
Datasheet
Manual type:
Datasheet
Pages:
1
Size:
80.1 KB
Language:
english
Revision:
Manual-ID:
Date:
Quality:
Scanned document, all readable.
Upload date:
March 7, 2014
MD5:
b74920da-bc0b-35a6-df62-c2274118643e
Downloads:
564
User manual
Manual type:
User manual
Pages:
142
Size:
5.7 MB
Language:
english
Revision:
A
Manual-ID:
182-901-01
Date:
October 1990
Quality:
Scanned document, all readable.
Upload date:
Aug. 21, 2018
MD5:
77c2cb1f-3fe2-4e71-7afc-39693528677f
Downloads:
688