.....obsolete user manuals, a lot of repair manuals, free service manuals, rare schematic diagrams, usefull service instructions, pdf books, how to repair instructions, lost operating manuals, old handbooks, tons of part lists, hidden service bulletins, your instruction books, informative repair tips, complete disassembly routines.....


What are you looking for?


Kenwood - CS-1012 - Oscilloscope
Manufacturer:
Equipment:
CS-1012
Date:
1991
Category:
Group:
Sub Group:

Information

Vertical axis has high sensitivity and wide bandwidth and especially covers fully specified frequency response at 2mV/div for all models. CS-1022, 1021 ; Dual Trace 1 mV/div : DC to 10 MHz, -3 dB 2mV/div : DC to 20 MHz, -3 dB CS-1012 ; Dual Trace 1 mV/div : DC to 7 MHz, -3 dB 2mV/div : DC to 10 MHz, -3 dB CS-1020 ; Single Trace 1 mV/div : DC to 10 MHz, -3 dB 2mV/div : DC to 20 MHz, -3 dB CS-1010 ; Single Trace 1 mV/div : DC to 7 MHz, -3 dB 2mV/div : DC to 10 MHz, -3 dB • Vertical sensitivity range is selectable from 1 mV/div to 5V/div with rotary switch continuously. • Time base permits the high sweep speed. CS-1022, 1020; 20nsec/div (x10 MAG) CS-1021, 1012, 1010; 50nsec/div (x10 MAG) • Vertical sensitivity error and sweep rate error are ±3% and accurate measurements are provided. • The 150 mm rectangular CRT with internal graticule provides high brightness and accurate measurements, free of parallax error. CS-1022, 1020; domed mesh type CRT with post deflection acceleration and high brightness phosphors (acceleration voltage; 6 kV). CS-1021, 1012, 1010; high brightness CRT (acceleration voltage; 2 kV). • For convenience in making rise time measurements, the 0%, 10%, 90% and 100% levels are marked on the graticule scale of the CRT. • Trace rotation is electrically adjustable from the front panel. • By SCALE ILLUM control, the waveform is easy observed in the dark and the photograph of the waveform is easy provided. (Except CS-1021) • Selectable AUTO FREE RUN function provides sweep without trigger input signal. • The FRAME-LINE switch provides selection of sync pulse for sweep triggering from small amplitude to large amplitude without adjusting when viewing composite video waveforms. • For CS-1022, 1021 and 1012, vertical mode automatically provides the trigger signal with TRIG SOURCE and V. MODE switches. • X-Y operation is easy provided by one-touche. CS-1022, 1021, 1012; CH1 Y axis, CH2 X axis CS-1020, 1010; VERT INPUT Y axis EXT TRIG INPUT X axis • CS-1022 and 1012 are provided with CH1 OUTPUT terminal to monitor input signal of CH1. • CS-1020 and 1010 are provided with VERT OUTPUT terminal to monitor input signal of VERT INPUT.

show more

3 Manuals

User manual
Manual type:
User manual
Pages:
31
Size:
5.9 MB
Language:
english
Revision:
Manual-ID:
B50-7570
Date:
December 1991
Quality:
Scanned document, all readable.
Upload date:
May 17, 2020
MD5:
75cc6fd6-6c3e-d817-f2e8-277923300051
Uploader:
Fabio
Downloads:
1190
Service manual
Manual type:
Service manual
Pages:
55
Size:
21.6 MB
Language:
english
Revision:
Manual-ID:
Date:
Quality:
Scanned document, reading partly badly, partly not readable.
Upload date:
Dec. 28, 2020
MD5:
2d1f213f-140e-5270-bf13-823c7c21bba5
Uploader:
Guidopianino
Downloads:
685
Service manual
Manual type:
Service manual
Pages:
87
Size:
11.9 MB
Language:
english
Revision:
Manual-ID:
Date:
Quality:
Scanned document, all readable.
Upload date:
Dec. 28, 2020
MD5:
1103c56c-9610-3dcd-cd3c-9fafffac145b
Downloads:
751