1.1 Equipment Description
The C0S6100M is a solid state, five channel, twelve trace,
100 MHz bandwidth, general purpose oscilloscope. Vertical
mode switching enables any combination of five channels to
be displayed simultaneously. Channels 1 (CHI) and 2 (CH2)
each has ten calibrated deflection factors from 5
millivolts/division to 5 volts/division selected in a 1-2-5
sequence. The horizontal deflection system has calibrated
sweep rates of 20 nanoseconds/division to 0.5 seconds/
division in 23 steps. A ten times magnifier expands each
horizontal sweep to maximum of 2 nanoseconds/division. An
X-Y display mode is provided via an X-Y selector switch.
1.2 Features
The features of the C0S6100M Oscilloscope can be summarized
as follows:
(1) Ease of use:
Light torque lever switches and pushbutton switches are used.
These and other controls are-laid out in the most convenient
locations making the oscilloscope extremely easy to operate.
(2) Clear waveform observation:
The cathode-ray tube is a 6-inch large-screen rectangular
type CRT with a red internal graticule of 80 mm x 100 mm
(3.15 in. x 3.94 in.) The red graticule produces a high
resolution background for easy waveform viewing.
(3) High acceleration voltage (20 kV):
The high acceleration voltage of the CRT ensures a bright
trace for observation and photography.
(4) High sensitivity and wide frequency bandwidth:
The maximum vertical sensitivity is 1 mV/DIV (with x5 MAG)
and the frequency response is 100 MHz or greater (-3 dB).
(5) High input impedance:
The input impedance of CHI, CH2, CH3, CH4 and CH5 (EXT TRIG)
is 1 MŒ ±1%, 20 pF ±2 pF, allowing the use of 10x Probes.
(6) 5-channel simultaneous display:
The C0S6100M employs a new type of vertical mode switching
circuit which enables display of any combination of CHI,
ADD (CHI ± CH2), CH2, CH3, and TRIG VIEW (CH4 and CH5). Up
to five channels can be displayed simultaneously; up to
twelve traces can be displayed when in the alternate sweep mode.
(7) Trigger level lock:
A new trigger level lock circuit eliminates the requirement
of triggering adjustments on most signals. (Manual control
is still available for triggering on complex waveforms.)
(8) Stable alternate triggering function:
When in the alternate triggering mode, stable triggering can
be attained even when the signals of CHI, CH2 and CH3 are
not time releated. (patent pending)
The-B END’S A switch is installed separately from the
holdoff control switch. Holdoff control can be used while in
the.
B END’S A mode.
(10) Maximum sweep time 2 nsec/DIV with xlO MAG function:
With the xlO MAG function, the highest sweep speed of 20
nsec/DIV can be multiplied by a factor of 10 to attain a
maximum sweep speed of 2 nsec/DIV.
(11) Alternate sweep:
The A sweep and the delayed sweep can be viewed
simultaneously in the alternate mode.
(12) Linear focus:
Once the beam focus is adjusted, it is automatically
maintained in this state regardless of changes in intensity.
(13) Multiple-channel X-Y operation:
By using the CH3-HOR channel as the X-axis input and all
other channels as the Y-axis inputs, up to four channels of
X-Y operation can be viewed.