MELAG Medical Technology Cliniklav 25 Autoclave
Manufacturer:
No picture available!
Maybe you can upload a pic for the
MELAG Medical Technology Cliniklav 25 ?
If you have any other manuals for the
MELAG Medical Technology Cliniklav 25 you can upload the files here.
Model:
Cliniklav 25
Date:
2011
Class:
Type:
SubType:
Manual type:
Service and User Manual
Pages:
50
Size:
498.05 Kbytes (510000 Bytes)
Language:
english
Revision:
5
Manual-ID:
Date:
01 January 2011
Quality:
Electronic document, no scan, very well readable.
Upload date:
08 January 2020
MD5:
b50a3023ecbac53c4514917d6e6e8f18
Downloads:
195
Information
CONTENTS
1
SAFETY INSTRUCTIONS ... 5
1.1
Symbols on the
Autoclave ... 5
2
DESCRIPTION OF THE UNIT ... 6
2.1
Views of the unit ... 6
2.2
Control panel ... 7
2.3
Performance features of this
Autoclave ... 8
2.3.1
Fractionating pulsed vacuum procedure ... 8
2.3.2
Programs for sterilization ... 8
2.3.3
Separate steam generation ... 8
2.3.4
One-way system/Conductivity measurement/Automatic water supply ... 8
2.3.5
Electronic Parameter Control (EPS) ... 8
2.3.6
Vacuum drying ... 8
2.3.7
Documentation ... 8
3
INSTALLATION AND INITIAL START-UP ... 9
3.1
3.2
3.3
3.4
3.5
3.6
3.7
Power supply ... 9
Connection of a water treatment unit ... 9
Vacuum test ... 9
Bowie & Dick test ... 11
Trial run ... 11
Record of installation and setting up ... 12
Validation ... 12
4
STERILIZATION ... 12
4.1
Supply with fresh purified feed water/cooling water ... 12
4.2
Preparation of instruments ... 12
4.3
Loading the
Autoclave ... 13
4.4
Program selection ... 14
4.5
Pre-heating ... 15
4.6
Selecting extra drying ... 15
4.7
Opening and closing the
Autoclave door ... 15
4.8
Program start ... 15
4.9
Program progress ... 16
4.10
Manual termination of program ... 17
4.10.1 Terminate before beginning of drying ... 17
4.10.2 Terminate during drying ... 18
4.11
Removing the sterilized items ... 19
4.12
Sterile storage ... 19
4.13
Display batch number ... 20
4.14
Display total batch number ... 20
5
LOGGING ... 21
5.1
Setting date and time ... 21
5.2
Log
Printer MELAprint®42 as output medium ... 23
5.2.1
Connecting the log
Printer MELAprint®42 ... 23
5.2.2
Initialising the log
Printer MELAprint®42 ... 23
5.3
Test output ... 24
5.4
Computer as output medium ... 25
5.5
Employing other devices as output medium ... 25
5.6
No output medium ... 25
5.7
Output of the logs ... 25
5.7.1
Automatic immediate log output ... 25
5.7.2
Output selected logs subsequently ... 26
5.7.3
Display protocol memory ... 27
5.7.4
Output all stored logs ... 28
5.7.5
Delete all stored logs ... 29
5.8
Read log files correctly ... 31
6
OPERATING PAUSES ... 31
6.1
Sterilization frequency ... 32
6.2
Shut-down/Transport ... 32
7
MAINTENANCE ... 32
7.1
7.2
7.3
7.4
7.5
7.6
7.7
Cleaning ... 32
Preparation of instruments ... 32
Rust formation = Drag-in rust ... 33
Use qualitatively high-grade feed water ... 33
Avoid formation of spots ... 34
Renewed Qualification ... 34
Maintenance recommendations ... 34
8
FUNCTION TEST ... 35
8.1
Water quality (conductivity) ... 35
8.2
Helix test body system MELAcontrol®/PRO ... 35
8.3
Continuous monitoring of sterilization process ... 35
9
OPERATIONAL9.1
9.2
9.3
9.4
9.5
9.6
4.
9.7
ERRORS/MALFUNCTIONS ... 36
Warning messages ... 36
Malfunction messages ... 38
Reaction to warnings/error messages ... 41
No display on the screen ... 42
Emergency measure if the electric door release button fails ... 42
Too large feed water consumption ... 43
Bad drying results ... 43
Program modifications ... 43
10
IMPORTANT INFORMATION REGARDING ROUTINE OPERATION ... 44
11
APPENDIX ... 44
11.1
Additional technical data ... 44
11.2
Nominal value tolerances ... 47
11.3
Instructions for drying ... 47
11.3.1 Drying in sterilization containers ... 47
11.3.2 Textiles ... 48
11.3.3 Instruments ... 49
11.3.4 Loading the
Autoclave ... 49
11.3.5 Loading containers with soft sterilization packing material ... 50
11.3.6 Stacking sterilization containers ... 50
11.3.7 Removing the sterilized items ... 50
11.3.8 Improving the drying ... 50
Comments