1. The 2018 is a 0.08 MHz to 520 MHz synthesized signal
generator providing calibrated output levels from 13 dBm to
-127 dBm. 2019 is a 0.08 MHz to 1040 MHz synthesized signal
generator similar to 2018 except that a frequency doubler
circuit enables it to cover frequencies up to 1040 MHz with
the same output level range. The output frequency of both
2018 and 2019 is phase locked to a frequency standard and
can be set to a resolution of 10 Hz at frequencies up to 520
MHz and to a resolution of 20 Hz above 520 MHz (2019 only).
2. Both instruments can be frequency modulated or amplitude
modulated from external or internal modulation sources. The
internal modulation source provides five fixed modulation
frequencies; re-selection of components within the
instrument allows alternative frequencies to be set if required.
3. Calibrated output levels from -127 dBm to +13 dBm (0.2 yV
to 2 V e.m.f.) in the c.w. and f.m. modes and up to +7 dBm
(1 V e.m.f.) in the a.m. mode are provided. A choice of nine
output level calibration units can be obtained on the front
panel. The r.f. output level can be set to a resolution of
0.1 dB or better over the entire output voltage range and
features a total cumulative accuracy of ±1 dB up to 520 MHz
(±2 dB, 520 MHz - 1040 MHz). Protection against the
accidental application of up to 50 W of reverse power is
provided by a fast responding reed relay.
4. Front panel operation is carried out by direct entry of
required settings via the keyboard. Microprocessor control
ensures maximum flexibility and allows programming by the
General Purpose Interface Bus (GPIB). This facility is
offered as an optional accessory enabling the instrument to
be used both as a manually operated bench instrument or as
part of a fully automated test system. Facility is also made
for the use of an external standard reference when this is
preferred.
5. A second function mode of operation includes means of
setting the GPIB address, selection of alternative r.f.
level calibration units, access to various calibration
routines and a facility to aid diagnostic fault finding.
4 Manuals
Service manual
Manual type:
Service manual
Pages:
261
Size:
12.2 MB
Language:
english
Revision:
2
Manual-ID:
H 52018-900S 46881-420J
Date:
Quality:
Scanned document, reading partly badly, partly not readable.
Upload date:
Feb. 20, 2016
MD5:
b5282509-2395-27e1-e637-2d6b3a9765ba
Downloads:
1244
User manual
Manual type:
User manual
Pages:
36
Size:
4.7 MB
Language:
english
Revision:
Manual-ID:
H 52018-900S 46881-419G
Date:
Quality:
Scanned document, all readable.
Upload date:
Feb. 20, 2016
MD5:
588ceed7-46fb-d9bb-b60c-4e77b134ed65
Downloads:
963
Service manual
Manual type:
Service manual
Pages:
181
Size:
21.4 MB
Language:
english
Revision:
4/85
Manual-ID:
H 5201S-900S 46881-420J
Date:
Quality:
Scanned document, all readable.
Upload date:
Feb. 20, 2016
MD5:
2279b4da-33b2-1062-e616-60c5bf74e5fc
Downloads:
1355
Service manual
Manual type:
Service manual
Pages:
284
Size:
37.6 MB
Language:
english
Revision:
Manual-ID:
H 52018-900S 46881-420J
Date:
Quality:
Scanned document, reading partly badly, partly not readable.
Upload date:
June 5, 2016
MD5:
6efb46f5-8f86-3c28-8261-ea2620d29c34
Downloads:
1114