.....obsolete user manuals, a lot of repair manuals, free service manuals, rare schematic diagrams, usefull service instructions, pdf books, how to repair instructions, lost operating manuals, old handbooks, tons of part lists, hidden service bulletins, your instruction books, informative repair tips, complete disassembly routines.....


What are you looking for?

extended search


Metron QA-1290 Analyzer
Manufacturer:
Model:
QA-1290
Date:
2003
Class:
Type:
SubType:
NIBP-Analyzer

Information

METRON’s QA-1290 NIBP Analyzer is a precision instrument, designed for use by trained service technicians, for verifying the performance of all types of adult and neonate oscillometric NIBP monitors. It does this in two stages. The first stage is auto-calibration. QA-1290 calibrates both the cuff and tubing in order to verify the NIBP monitor used. Then, the QA-1290 performs calibrated simulations under all conditions. The QA-1290 provides for dynamic performance testing using both real and simulated blood pressure waveforms. Blood pressure waveforms include individual settings for systolic BP, diastolic BP, heart rate, and the pulse volume/amplitude. The QA-1290 also simulates calibrated artifact and arrhythmias in a large variety of real-life conditions. It provides high/low pressure release verification and automated leak testing. It also generates user selectable pressure levels to calibrate a variety of pressure monitors. Highlights: • High performance, compact design, simple to use • Performs a complete test including cuff and tubing • Large selection of adult and infant preset BP conditions • Programmable customized patient conditions • Simulation of real-life artifact and arrhythmia conditions such as: Bradycardia, Tachycardia, Geriatric Patient, Obese Patient, Strenuous and Mild Exercise, Weak Pulse, Premature Atrial Contraction, Premature Ventricular Contraction, 2nd Degree Heart Block, Atrial Fibrillation. • Digital manometer with automatic or manual inflation of the cuff pressure for Leak Test and Over Pressure Cut-off Test • Updates and enhancements of internal firmware via the RS-232

show more

Service and User Manual
Manual type:
Service and User Manual
Pages:
65
Size:
1.31 Mbytes (1377156 Bytes)
Language:
english
Revision:
1.66
Manual-ID:
17525
Date:
2003 01 14
Quality:
Electronic document, no scan, very well readable.
Upload date:
2019 08 16
MD5:
929c01d5444c3d1ed53a873e27bd9447
Downloads:
444

Information

1. 2. 3. 4. 5. 6. INTRODUCTION ... 1-1 1.1 Features ... 1-1 1.2 Specifications ... 1-2 1.3 General Information ... 1-3 INSTALLATION ... 2-1 2.1 Receipt, Inspection and Return ... 2-1 2.2 Setup ... 2-2 2.3 Connecting the Device under Test ... 2-2 2.4 Ansur plug in QA-1290 ... 2-4 OPERATING QA-1290, ... 3-1 3.1 Control Switches and Connections ... 3-1 3.2 QA-1290’s Controls ... 3-2 3.3 QA-1290 Startup ... 3-3 3.4 QA-1290 Main Menu ... 3-3 3.5 Configuring QA-1290, ... 3-4 3.6 Printing Results ... 3-6 3.7 Upgrading QA-1290 Firmware ... 3-7 BLOOD PRESSURE TESTING ... 4-1 4.1 Measuring Cuff Volume ... 4-1 4.2 Setting Test Parameters ... 4-2 4.3 Running BP Tests ... 4-6 LEAK, MANOMETER, AND OVER-PRESSURE CUT-OFF TESTING ... 5-1 5.1 Leak Test ... 5-1 5.2 Over-Pressure Cut-Off Test ... 5-3 5.3 Manometer ... 5-4 TESTING AND MAINTENANCE ... 6-1 6.1 Required Equipment ... 6-1 6.2 Testing Procedures ... 6-1 6.3 Cleaning and Sterilization ... 6-2 7. CALIBRATING QA-1290 ... 7-1 7.1 Calibration ... 7-1 8. COMPONENT FUNCTIONS AND PARTS ... 8-1 8.1 System Overview ... 8-1 8.2 QA-1290 Pressure Measurement System ... 8-2 8.3 Processor System ... 8-4 8.4 Pneumatic System ... 8-5 8.5 Power supply ... 8-6 8.6 Connector Signals ... 8-6 8.7 Component Parts ... 8-9 APPENDIX A – TUBING KIT COMPONENTS ... A-1 APPENDIX B – SCHEMATIC DIAGRAMS ... B-1 APPENDIX C – ERROR REPORT FORM ... C-1 APPENDIX D – IMPROVEMENT SUGGESTION FORM ... D-1

show more