Tektronix DC 504 Counter
Manufacturer:
Model:
DC 504
Date:
1984
Class:
Type:
SubType:
Counter/Timer
Information
The
DC 504 Counter/Timer measures frequency from 0.1 Hz (0
Hz with 0.1 Hz resolution) to at least 80 MHz. It measures
period from 1"s to 999.99 s, and totalizes events from 0 to
99,999 at a maximum rate of at least 80 MHz. A resolution of
0.1 Hz can be obtained by allowing the more significant
figures of the
Counter to overflow.
Five 7-segment light-emitting diodes (LED) provide a highly
visible numerical display. The decimal point is
automatically positioned and leading zeros (to the left of
the most significant digit or decimal point) are blanked.
Digit overflow is indicated by a front-panel LED.
Signals to be counted or timed can be applied to either a
front-panel bnc connector or to the rear
Interface
connector. The
DC 504 is designed to operate in any of the
TM 500-Series Power Modules. It is completely compatible
with other members of the TM 500 family in terms of signal
interconnections.
The
DC 504 is designed to operate in ambient temperatures
between 0°Cand +50° C. It can be stored in temperatures
ranging from -40°Cto 4-75° C. After storage in temperatures
outside the specified operating temperatures, allow the DC
504 to return to a room ambient temperature within the
operating range before applying power.
Manual type:
Service and User Manual
Pages:
59
Size:
14.09 Mbytes (14776102 Bytes)
Language:
english
Revision:
revised
Manual-ID:
070-1670-01
Date:
1984 12 01
Quality:
Scanned document, all readable.
Upload date:
2017 12 30
MD5:
f8f8a53921c5448eaefa176beb8356c2
Downloads:
669
Information
Page OPERATORS PART—ENGLISH OPERATING INSTRUCTIONS
INSTRUMENT DESCRIPTION ...
PREPARATION FOR USE ...
Installation and Removal ...
Controls and Connectors ...
INPUT CONSIDERATIONS ...
Input Sources ...
Triggering ... 1-4
Measurement Intervals ... 1-4
Maximum Input Volts, Sensitivity, and
Frequency ...
Range ...
Setting Slope and Level ... 1-4
APPLICATIONS ...
Frequency Measurements ... 1-6
Revolutions Per Minute (RPM)
Measurements ...
Totalizing ...
Period Measurements ...
FUNCTIONS AVAILABLE AT REAR
Interface CONNECTOR CONTROL
LINES ...
Signal Lines ...
Section 2 SPECIFICATION AND PERFORMANCE
CHECK 2-1
Performance Conditions ... 2-1
Table 2-1.Electrical Characteristics . 2-1
Table 2-2. Environmental
Characteristics ... 2-3
Performance Check ... 2-4
Section 3 ADJUSTMENT ... 3-1
Section 4 MAINTENANCE ... 4-1
Section 5 CIRCUIT DESCRIPTION ... 5-1
Section 6 REPLACEABLE ELECTRICAL PARTS
LIST ... 6-1
OPTIONS
Section 7 DIAGRAM AND CIRCUIT BOARD
ILLUSTRATION ... 7-1
Section 8 REPLACEABLE MECHANICAL PARTS
LIST AND EXPLODED VIEW ... 8-1
CHANGE INFORMATION
Comments