Tektronix WFM6100 Analyzer
Manufacturer:
Model:
WFM6100
Date:
unknown
Class:
Type:
SubType:
Waveform Monitor
Information
The key features for all models include:
High-resolution XGA display with the FlexVuTM
Interface and high-quality waveform processing, providing outstanding
picture and signal displays and exceptional flexibility in creating multi-view displays.
Extensive fault detection, alarm generation, error logging and status reporting, including quality statistics on both
video and audio content.
Up to four independent picture displays of the monitored input that can show different safe area graticules and decoded
closed caption services.
Proprietary Split Diamond and Arrowhead displays that help quickly detect and correct gamut problems.
Sophisticated audio level and phase displays, including an exclusive display for surround sound audio, which helps
reduce time and effort in creating and verifying audio content.
A proprietary Timing display that graphically shows the timing relationship between the input signal and an external
reference signal or a saved offset. This easy-to-interpret display, along with numeric readouts of vertical and horizontal
timing relationships, reduces time and effort in verifying and correcting signal timing.
User-defined menus (MyMenu) give easy access to frequently used operations and simplify instrument operations.
Up to 20 instrument presets organized in four groups of five presets per group for easy access, with user-definable
labels for quick identification.
A front-panel USB 2.0 port for easily storing and recalling captured data and instrument presets.
A convenient front-panel headphone port for quickly verifying sound quality. Simple touch screen controls let you quickly
check the stereo pairs shown on the audio bar display.
Network access and control through a simple, Web-page
Interface, a more complete Java-based remote control
Interface,
or by SNMP. Ground-closure remote control port with an alarm output and support for recalling instrument presets.
Support for printing the display and event log on USB printers.
WFM6100 and
WFM7100 only:
CaptureVuTM capability that can capture a full frame of video data and can compare live to captured data on the
waveform, vector, gamut, and picture displays. Data can be captured using the touch-screen menu or triggered by up
to 14 alarm conditions. Captured data can be stored on a USB flash drive for transfer to another instrument or to
a PC for more in-depth analysis.
Up to four independent displays of the signal characteristics of an SDI input, including Eye diagrams and measurements,
jitter readouts and bar display, jitter waveform display, and SDI status screen.
Two independent jitter measurements with separate high pass filters that offer simultaneous display of peak-to-peak
amplitudes of timing and alignment jitter.
Cable loss measurement with source level and cable length estimates based on user-specified cable type.
Extensive support for monitoring
Dolby audio content, including auto-sensing
Dolby formats, decoding
Dolby content and
automatically configuring the appropriate audio level and phase displays, and showing decoded
Dolby metadata.
Manual type:
User Manual
Pages:
150
Size:
6.89 Mbytes (7222926 Bytes)
Language:
english
Revision:
Manual-ID:
071-1890-01
Date:
unknown
Quality:
Electronic document, no scan, very well readable.
Upload date:
2020 07 27
MD5:
e0786899b11d2411b86d2cc8737e7b6f
Downloads:
1116
Information
Quick Start User Manual
General Safety Summary ... iii
Environmental Considerations ... v
Preface ... vi
Key Features ... vi
Documentation ... viii
Conventions Used in this Manual ... viii
Before Installation ... 1
Check Package Contents ... 1
Standard
Accessories ... 1
Optional
Accessories ... 1
Options ... 2
Installation ... 4
Connecting Power and Powering On/Off ... 4
Installing the Monitor in a Video System ... 4
How to Operate Your Instrument ... 7
Overview ... 7
Front Panel Controls and Connectors ... 11
Elements of the Display ... 13
Rear-Panel Connectors ... 16
To Select a Measurement ... 25
To Set Display and Measurement Parameters ... 26
To Select Among Video Inputs ... 26
To Set Gain, Horizontal Magnification and Sweep ... 28
To Use Presets ... 30
To Measure Waveforms with Cursors ... 39
To Capture the Display ... 40
To Set Line Select Mode ... 46
To Adjust Headphone Volume and Source ... 47
To Con figure Your Instrument ... 48
To Use Online Help ... 49
To Connect to a Network ... 51
To Connect Directly to a PC ... 54
To Print Screens and Event Logs ... 54
To Create a User Menu ... 58
Waveform Display ... 61
Vector Display ... 63
Picture Display ... 64
Audio Display ... 65
Lightning Display ... 69
Diamond Display ... 70
Arrowhead Display ... 71
Timing Display ... 72
Bowtie Display ... 75
DataList Status Display ... 76
ANC Data Display ... 77
Status Displays ... 78
Eye Display ... 82
Jitter Display ... 84
SDI Status Display ... 85
Monitoring the SDI Physical Layer ... 86
To Con figure the Physical Layer Settings ... 86
To Take Eye Measurements ... 92
Timing a Studio ... 97
Using the Timing-Display Method ... 97
Timing Multiple Inputs to a Router ... 99
Checking Chroma/Luma Delay (Lightning Display) ... 102
Checking Gamut ... 105
Setting up for Gamut Checks ... 105
Checking RGB Gamut ... 107
Checking Composite Gamut ... 109
Checking Luma Gamut ... 110
Automating Gamut Checks ... 111
Adjusting Gamut Limits ... 112
Selecting and Monitoring Audio ... 114
Selecting the Audio Input ... 114
Checking Audio Level & Phase ... 116
Checking Surround Sound ... 118
Remote Communications ... 124
Using the Remote Web
Interface ... 124
Using the Remote Application ... 125
To Upgrade the Waveform Monitor
Software ... 127
PC System Requirements ... 127
Before You Begin ... 127
Installing the
Software ... 128
Verifying the Upgrade ... 130
Specifications ... 133
Index
Manual type:
Service Manual
Pages:
76
Size:
3.28 Mbytes (3434958 Bytes)
Language:
english
Revision:
Manual-ID:
077-0090-00
Date:
2008 01 01
Quality:
Electronic document, no scan, very well readable.
Upload date:
2020 07 29
MD5:
11bc81b13e1baa7685052e000d8b2874
Downloads:
1368
Information
This manual supports servicing to the module level of the
WFM6100
WFM7000, and
WFM7100 Waveform Monitors With Option FP, which process
video signals for display on an internal XGA LCD. The instrument is a monitor
for broadcasting, production, and post-production environments.
This manual explains how to troubleshoot and service the monitor to the module
level. The manual is divided into the following sections:
H
Introduction provides a general product description and tells where to find
product installation information.
Theory of Operation provides descriptions of the
WFM6100 and WFM7000
Series Waveform Monitors modules.
Maintenance tells you how to troubleshoot the product to the module level
and how to handle the modules.
Replaceable Parts illustrates the replaceable modules and mechanical parts,
and provides replacement part numbers.
Comments