Product Description
The
Tektronix WVR 500 is a half-rack wide, one rack unit high,
rasterizing television waveform/vector/picture monitor with NTSC
and PAL capability. Without a built-in display device, it outputs a
display signal that can be connected to a remote monitor or video
switcher.
Traditional applications for this monitor include areas of production,
postproduction, and transmission of television signals. Untraditional
applications include remote video monitoring of unmanned video
uplinks/downlinks and television transmitters.
Key Features
The
WVR500 utilizes the following key features:
Rasterized output which can display the waveform/vector/picture
monitor displays simultaneously
Menu-assisted monitoring operation
Two channels of video inputs and two video outputs
Complete instrument operation possible through the RS-232
remote port
Amplitude alarm for the waveform display
Ability to store/recall four instrument setups
Adjustable signal and graticule display colors
Instrument calibration performed from the front panel
Universal power supply automatically accommodating AC
supplies from 90–250 V, 50–60 Hz
Rasterized Display. The WVR 500 utilizes a proprietary rasterizer
which displays analog-like waveforms and vectors and the remote
monitor simultaneously with the appropriate measurement graticule.
The rasterized waveform and vector displays can fill the entire
display or be reduced to 1/4-screen sized windows over the picture
display. The reduced windows can be made transparent for complete
viewing of the picture display.
Menus. The WVR 500 menus use a combination of on-screen readout
and multi-use buttons, in conjunction with a general-purpose
adjustment knob, to control most of its monitoring functions.
RS–232 Port. The RS-232 remote connector enables remote
instrument operation. All front-panel controls and menu selections
can be operated through this port.
Alarm Mode. For the waveform monitor display only, there is an
Alarm mode which highlights any portion of the displayed signal
that exceeds the 100 IRE (1.0 V PAL) graticule line.
Calibration. The WVR 500 can be calibrated entirely from the front
panel after the movement of an internal jumper. Refer to the
WVR500 Waveform/Vector Monitor Service Manual for instructions
on how to calibrate the instrument.
Service manual
Manual type:
Service manual
Pages:
124
Size:
984.2 KB
Language:
english
Revision:
Manual-ID:
070-8897-01
Date:
Quality:
Electronic document, no scan, very well readable.
Upload date:
Dec. 30, 2017
MD5:
da9be332-311f-eb49-dd59-e3fcbf382687
Downloads:
323
User manual
Manual type:
User manual
Pages:
106
Size:
449.9 KB
Language:
english
Revision:
Manual-ID:
070-8927-05
Date:
Quality:
Electronic document, no scan, very well readable.
Upload date:
Sept. 15, 2019
MD5:
b886f139-ebb5-ae2e-7c26-63375c37fde6
Downloads:
163