.....obsolete Bedienungsanleitungen, eine Menge Reparaturanleitungen, kostenlose Serviceanleitungen, seltene Schaltpläne, nützliche Serviceanleitungen, pdf-Bücher, Reparaturanleitungen, verlorene Bedienungsanleitungen, alte Handbücher, tonnenweise Teilelisten, versteckte Service Bulletins, Ihre Bedienungsanleitungen, informative Reparaturtipps, komplette Demontageanleitungen.....


Wonach suchen Sie?


Fluke - 1912A - Frequenzzähler
Hersteller:
Gerät:
1912A
Datum:
1977
Kategorie:
Gruppe:
Untergruppe:

Informationen

These rugged counters are at home on the production line, in the lab, or in the field and do the work of counters costing much more. They measure frequencies to 125 MHz, 250 MHz or 520 MHz (depending on model), period of signals to 2 MHz, period average to 10 ps resolution and totalize to 9,999,999 counts. Autorange Full autoranging is supplemented by selectable four-range manual operation. In autorange, the display is automatically filled to a maximum 7-digit readout. A unique hysteresis capability eliminates undesirable up-and-down ranging for between-range signals. Autoreset This automatic feature is activated every time you select a new range orfunction, which means you never have to wait for a second reading, the first one in the new measurement sequence is always correct. Autoreset saves time and reduces errors. Automatic Clean Dropout The 1911A and 1912A Channel B input has a circuit which automatically monitors the input and gives you instant warning in the form of zero readout whenever your input signal falls below the sensitivity threshold of the trigger circuit. When the signal level returns to an acceptable level, the counter locks on for a correct reading. Sensitivity A basic sensitivity of 15 mV, backed by Fluke’s conservative design margin, guarantees you will get reliable, solid readings every time. In practice, a typical sensitivity of 10 mV will be experienced. Versatile Time Bases The standard 0.5 ppm per month timebase assures excellent long term stability for bench, production or field use. A convenient rear panel external timebase input jack and switch let you operate from your own 10 MHz frequency standard at any time. Choice of optional time bases with improved aging rates and temperature stabilities allows you to purchase only as much stability as you’ll need in your applications. Input Signal Conditioning Each counter offers trigger level and attenuator controls which operate over the dynamic range of the input to permit accurate readings in the presence of noise. Even ringing TTL signals can be accurately measured. In addition, the 1911A offers a separate 50 ohm input for 50 MHz to 250 MHz and the 1912A does the same but goes to 520 MHz. Battery Portability All three counters are available with rechargeable batteries for field portability. Order 1910A -01,1911A-01, or 1912-01. Four hours minimum operation gives you plenty of opportunity to solve those tough field service problems

mehr

2 Handbücher

Bedienungsanleitung mit Schaltplan
Dokumenttyp:
Bedienungsanleitung mit Schaltplan
Seitenanzahl:
130
Größe:
4,8 MB
Sprache:
Englisch
Revision:
1 2/79
Dokument-ID:
467746
Datum:
Qualität:
Gescanntes Dokument, alles ist lesbar.
Upload Datum:
19. Februar 2009
MD5:
bee6ced6-9acf-87ee-f54d-bb1fc019a3be
Downloads:
1905
Produktblatt
Dokumenttyp:
Produktblatt
Seitenanzahl:
2
Größe:
301,4 KB
Sprache:
Englisch
Revision:
Dokument-ID:
Datum:
Qualität:
Gescanntes Dokument, teilweise schwer oder teilweise nicht zu lesen.
Upload Datum:
28. Januar 2016
MD5:
8fe721a4-3066-4173-5f88-fd786be0f3f8
Downloads:
1374