.....obsolete Bedienungsanleitungen, eine Menge Reparaturanleitungen, kostenlose Serviceanleitungen, seltene Schaltpläne, nützliche Serviceanleitungen, pdf-Bücher, Reparaturanleitungen, verlorene Bedienungsanleitungen, alte Handbücher, tonnenweise Teilelisten, versteckte Service Bulletins, Ihre Bedienungsanleitungen, informative Reparaturtipps, komplette Demontageanleitungen.....


Wonach suchen Sie?


Hewlett Packard - 11971 - Generator
Hersteller:
Gerät:
11971
Datum:
1985
Kategorie:
Gruppe:
Untergruppe:

Informationen

The HP Models 1197IK, 11971 A, 11971Q, 1197IU and 11971V are general-purpose harmonic mixers with very flat frequency response characteristics and low conversion loss. Collectively, they cover the frequency range of 18 to 75 GHz. The 1197 IK covers 18 to 26. 5 GHz, the 11971A covers 26.5 to 40 GHz, the 1197 IQ covers 33 to 50 GHz, the 11971U covers 40 to 60 GHz and the 11971V covers 50 to 75 GHz. The overall local oscillator (LO) frequency range of the HP 11971 Series Mixers is 2.0 to 4.5 GHz. Each model in the series employs a different LO harmonic, and as a result has a different LO range within the overall range of the series. The LO ranges of these mixers make them fully compatible with the HP Model 8569B Spectrum Analyzer. The HP 11971 Mixers use the HP Model 11975A Amplifier to raise the LO power to their required LO power level of +14 to +18 dBm. By taking advantage of the power leveling capability of the HP 11975A. The mixers are able to achieve maximum measurement accuracy at their optimum LO input level of +16 dBm. (See also Signal Analyzer High Power LO Options below.) A label on the top of each mixer shows a Conversion Loss Calibration graph plotted especially for that particular mixer. An 8-1/2 by 11-inch calibration table shipped with the mixer provides a larger, easier to read version of the same graph shown on the label, plus a list which shows the conversion loss and reference level offset at significant points across the mixer’s frequency range. The calibration table, accurate to ±2 dB. can be employed for absolute amplitude measurements. Also supplied with each mixer are five screws (four required) for attaching the mixer RF input flange to the waveguide.

mehr

1 Handbuch

Reparatur und Bedienungsanleitung
Dokumenttyp:
Reparatur und Bedienungsanleitung
Seitenanzahl:
52
Größe:
1,5 MB
Sprache:
Englisch
Revision:
Dokument-ID:
11971-90014
Datum:
August 1985
Qualität:
Gescanntes Dokument, teilweise schwer oder teilweise nicht zu lesen.
Upload Datum:
31. Mai 2020
MD5:
e6800632-c838-dfaa-a9a0-61e6fd917a16
Downloads:
148