.....obsolete user manuals, a lot of repair manuals, free service manuals, rare schematic diagrams, usefull service instructions, pdf books, how to repair instructions, lost operating manuals, old handbooks, tons of part lists, hidden service bulletins, your instruction books, informative repair tips, complete disassembly routines.....


What are you looking for?


Fluke - 8062A - Digital multimeter
Manufacturer:
Equipment:
8062A
Date:
1982
Category:
Group:
Sub Group:

Information

Your Fluke Model 8062A is a handheld, microcomputer-based 4-1/2 digit multimeter that is ideally suited for use in the field, laboratory, shop or home. The 8062A has all the features that have become accepted standards for quality handheld multimeters, as well as some new features that have not been offered before in a handheld multimeter. New features include the following: · True rms measurements for ac signals up to 30 kHz. · Resistance measurements up to 300 MW. · Ability to store any input signal as an offset or relative reference value. Other features include: · FUNCTIONS: Standard DMM measurement functions, such as ac and dc volts and ac and dc current, as well as resistance, continuity, and diode test. · RANGES: Leading zero suppression. Automatic polarity. Overrange indication. Protection from overloads and transients up to 1500V peak. Dual-slope integration a/d conversion to ensure noise-free measurements. Autoranging MW resistance range (to 300 MW), as well as four fixed resistance ranges from 200W to 200 kW. · OPERATOR CONVENIENCE: 4-1/2 digit Liquid Crystal Display Software control self-test routines for quick verification of internal circuitry and operation. · POWER: 170 hours of continuous operation can be expected from a 9V alkaline battery (NEDA 1604).

show more

3 Manuals

Service and user manual
Manual type:
Service and user manual
Pages:
124
Size:
5.9 MB
Language:
english
Revision:
1
Manual-ID:
PN 609153
Date:
Quality:
Electronic document, no scan, very well readable.
Upload date:
Nov. 29, 2014
MD5:
123949df-8aa2-ef1b-a8f4-b27d8afbee09
Downloads:
1267

Information

This manual pertains to instruments with serial number 6830XXX or higher. 1 Introduction and Specifications... 1-1 1-1. Introduction ... 1-3 1-2. Specifications... 1-4 2 Operation Instructions... 2-1 2-1. Introduction ... 2-3 2-2. Unpacking Your Instrument... 2-3 2-3. Battery Installation or Replacement ... 2-3 2-4. Fuse Replacement ... 2-5 2-5. Physical Features ... 2-6 2-6. Front Panel... 2-6 2-7. Display... 2-8 2-8. Signal Input Limits ... 2-9 2-9. Operation ... 2-10 2-10. Power-On Self-Test... 2-10 2-11. AC/DC Voltage (V) ... 2-11 2-12. True RMS Measurement ... 2-11 2-13. AC-Coupled AC Measurements... 2-12 2-14. Waveform Comparison and Conversion ... 2-13 2-15. High Impedance DC Voltage ... 2-14 2-16. AC/DC Current (A)... 2-15 2-17. Resistance (W)... 2-18 2-18. Autoranging Megohms... 2-19 2-19. Autoranging Kilohms... 2-20 2-20. Diode Test (G)... 2-21 2-21. Relative (REL) ... 2-22 2-22. Continuity ( ) ... 2-25 2-23. Initial Check-Out Procedure ... 2-25 3 Theory of Operation ... 3-1 3-1. Introduction ... 3-3 3-2. Functional Description... 3-3 3-3. Microcomputer... 3-3 3-4. Measurement Acquisition Chip (MAC) ... 3-5 3-5. A/D Converter Cycle... 3-5 3-7. Current Measurement ... 3-9 3-8. Resistance Measurement... 3-10 3-9. Continuity Measurement ... 3-11 4 Maintenance... 4-1 4-1. Introduction ... 4-3 4-2. Service Information ... 4-3 4-3. General Information ... 4-5 4-4. Handling Precautions for Using Static Sensitive Devices ... 4-5 4-5. Disassembly and Reassembly ... 4-5 4-6. Calibration and Backup Fuse Access... 4-6 4-7. Main PCB Access... 4-7 4-8. LCD and Microcomputer PCB Disassembly and Assembly ... 4-8 4-9. Backup Fuse Replacement... 4-11 4-10. Cleaning... 4-11 4-11. Performance Tests ... 4-12 4-12. Initial Procedure ... 4-12 4-13. Microcomputer and Display Test... 4-12 4-14. Voltage Test... 4-13 4-15. Resistance Test ... 4-14 4-16. Continuity Test ... 4-15 4-17. Current Test ... 4-15 4-18. Diode Test ... 4-17 4-19. Calibration Adjustments ... 4-17 4-20. Troubleshooting... 4-19 4-21. Self-Tests... 4-19 4-22. Ratio Self-Test ... 4-19 4-23. Switch Decoding Self-Test ... 4-20 4-24. Troubleshooting Guide ... 4-21 5 List of Replaceable Parts... 5-1 5-1. Introduction ... 5-3 5-2. How to Obtain Parts ... 5-3 5-3. Manual Status Information ... 5-4 5-4. Newer Instruments... 5-4 5-5. Service Centers... 5-4 6 Accessory Information ... 6-1 6-1. Introduction ... 6-3 6-2. Deluxe Carrying Case (C90)... 6-3 6-3. Temperature Probe (80T-150C and 80T-150F) ... 6-3 6-4. Current Transformer (80I-600)... 6-6 6-5. High Voltage Probe 80K-6 6-6 6-6. High Voltage Probe 80K-40 6-7 6-7. High Frequency Probe (83RF) ... 6-7 6-8. High Frequency Probe (85RF) ... 6-8 6-9. Current Shunt (80J-10)... 6-9 6-10. AC/DC Current Probe Y8100 6-9 6-11. AC Current Transformer (Y8101)... 6-10 6-12. Safety Designed Test Lead Set (TL70) ... 6-11 6-13. Deluxe Test Lead Set (Y8134)... 6-11 6-14. Slim Flex Test Lead Set (Y8140)... 6-12 6-15. Cables and Adapters ... 6-12 7 Schematic Diagrams... 7-1

show more

Service and user manual
Manual type:
Service and user manual
Pages:
96
Size:
5.8 MB
Language:
english
Revision:
3
Manual-ID:
632695
Date:
Quality:
Scanned document, all readable.
Upload date:
Jan. 27, 2016
MD5:
3f399ef1-2167-4fe1-22ee-7905cd4d8d06
Downloads:
653

Information

1 INTRODUCTION AND SPECIFICATIONS ...1-1 l-l. INTRODUCTION...1-1 1-2. SPECIFICATIONS...1-2 2 OPERATING INSTRUCTIONS ...2-1 2-1. INTRODUCTION...2-1 2-2. UNPACKING YOUR INSTRUMENT...2-1 2-3. BATTERY INSTALLATION OR REPLACEMENT .. 2-1 2-4. FUSE REPLACEMENT ...2-3 2-5. PHYSICAL FEATURES...2-3 2-6. Front Panel...2-3 2-7. Display...2-6 2-8. SIGNAL INPUT LIMITS ...2-6 2-9. OPERATION...2-7 2-10. Power-On Self Test ...2-7 2-11. AC/DC VOLTAGE (V) ...2-8 2-16. AC/DC Current (A) ...2-12 2-17. Resistance (il)...2-14 2-20. Diode Test...2-16 2-21. Relative (REL) ...2-17 2-22. Continuity ( -n-»»I ) ...2-19 2-23. INITIAL CHECK-OUT PROCEDURE ...2-20 3 THEORY OF OPERATION ...3-1 3-1. INTRODUCTION...3-1 3-2. FUNCTIONAL DESCRIPTION ...3-1 3-3. Microcomputer...3-1 3-4. Measurement Acquisition Chip (MAC) ...3-3 3-5. A/D Conversion Cycle ...3-3 3-6. Voltage Measurement ...3-5 3-7. Current Measurement ...3-6 3-8. Resistance Measurement...3-7 3-10. Continuity Measurement ...3-7 i (continued on page ii) 4 MAINTENANCE...4-1 4-1. INTRODUCTION...4-1 4-2. SERVICE INFORMATION...4-2 4-3 GENERAL INFORMATION...4-2 4-4. Handling Precautions for Using Static Sensitive Devices...4-2 4-5. Disassembly and Reassembly...4-3 4-9. Backup Fuse Replacement...4-8 4-10. Cleaning...4-8 4-11. PERFORMANCE TESTS...4-9 4-12. Initial Procedure...4-9 4-13. Microcomputer and Display Test...4-9 4-14. Voltage Test...4-9 4-15. Resistance Test...4-9 4-16. Continuity Test...4-10 4-17. Current Test...4-12 4-18. Diode Test...4-12 4-19. CALIBRATION ADJUSTMENTS...4-12 4-20. TROUBLESHOOTING...4-14 4-21. Self-Tests...4-15 4-24. Troubleshooting Guide...4-16 5 LIST OF REPLACEABLE PARTS...5-1 5-1. INTRODUCTION...5-1 5-2. HOW TO OBTAIN PARTS...5-2 5-3. MANUAL STATUS INFORMATION...5-2 5-4. NEWER INSTRUMENTS...5-2 5-5. SERVICE CENTERS...5-2 6 ACCESSORY INFORMATION...6-1 6-1. INTRODUCTION...6-1 6-2. DELUXE CARRYING CASE (C90)...6-1 6-3. TEMPERATURE Probe (80T-150C and 80T-I50)...6-1 6-4. CURRENT TRANSFORMER (801-600)...6-4 6-5. HIGH VOLTAGE Probe 80K-6 6-4 6-4. HIGH VOLTAGE Probe 80K-40 6-4 6-7 HIGH FREQUENCY Probe (83RF)...6-5 6-8 HIGH FREQUENCY Probe (85RF)...6-5 6-9. BATTERY ELIMINATOR (A81)...6-6 6-10. CURRENT SHUNT (80J-10)...6-6 6-11. AC/DC CURRENT Probe Y8100 6-7 6-12. AC CURRENT TRANSFORMER (Y8101)...6-8 6-13. SAFETY DESIGNED TEST LEAD SET (Y8132)...6-8 6-14. DELUXE TEST LEAD SET (Y8134)...6-8 6-15. SLIM FLEX TEST LEAD SET (Y8140)...6-8 6-16. CABLES AND ADAPTERS...6-9 7 SCHEMATIC DIAGRAMS...7-1

show more

Service and user manual
Manual type:
Service and user manual
Pages:
100
Size:
3.6 MB
Language:
english
Revision:
Manual-ID:
P/N 632695
Date:
March 1982
Quality:
Scanned document, reading partly badly, partly not readable.
Upload date:
Aug. 10, 2017
MD5:
7041d10e-91f9-21d3-65d9-a94d76964009
Downloads:
753

Information

Instruction Manual INTRODUCTION AND SPECIFICATIONS ...1-1 1-1. INTRODUCTION...M 1-2. SPECIFICATIONS.,...1-2 2 OPERATING INSTRUCTIONS ...2-1 2-1. INTRODUCTION...2-1 2-2. UNPACKING YOUR INSTRUMENT...2-1 2-3. BATTERY INSTALLATION OR REPLACEMENT .. 2-1 2-4. FUSE REPLACEMENT ...2-3 2-5. PHYSICAL FEATURES ...2-3 2-6. Front Panel...2-3 2-7. Display...2-6 2-8. SIGNAL INPUT LIMITS ...2-6 2-9. OPERATION ...2-7 2-10. Power-On Self Test ...2-7 2-11. AC/DC VOLTAGE (V) ...2-8 2-16. AC/DC Current (A) ...2-12 2-17. Resistance (O)...2-14 2-20. Diode Test...2-16 2-21. Relative (REL) ...2-17 2-22. Continuity (-*♦■>!! ) ...2-19 2-23. INITIAL CHECK-OUT PROCEDURE ...2-20 3 THEORY OF OPERATION ...3-1 3-1. INTRODUCTION...3-1 3-2. FUNCTIONAL DESCRIPTION ...3-1 3-3. Microcomputer...3-1 3-4. Measurement Acquisition Chip (MAC) ...3-3 3-5. A/D Conversion Cycle ...3-3 3-6. Voltage Measurement ...3-5 3-7. Current Measurement ...3-6 3-8. Resistance Measurement ...3-7 3-10. Continuity Measurement ...3-7 MAINTENANCE ...4-1 4-1. INTRODUCTION ...4-1 4-2. SERVICE INFORMATION ...4-1 4-3. GENERAL INFORMATION ...4-2 4-4. Handling Precautions for Using Static Sensitive Devices 4-2 4-5. Disassembly and Reassembly...4-3 4-9. Backup Fuse Replacement ...4-8 4-10. Cleaning...4-8 4-11. PERFORMANCE TESTS...4-9 4-12. Initial Procedure ...4-9 4-13. Microcomputer and Display Test ...4-9 4-14. Voltage Test ...4-9 4-15. Resistance Test ...4-9 4-16. Continuity Test...4-10 4-17, Current Test ...4-12 4-18. Diode Test...4-12 4-19. CALIBRATION ADJUSTMENTS ...4-12 4-20. TROUBLESHOOTING ...4-14 4-21. Self-Tests ...4-14 4-24. Troubleshooting Guide ...4-15 5 LIST OF REPLACEABLE PARTS ...5-1 5-1. INTRODUCTION...5-1 5-2. HOW TO OBTAIN PARTS ...5-1 5-3. MANUAL CHANGE AND BACKDATING INFORMATION...5-2 6 ACCESSORY INFORMATION...6-1 6-1. INTRODUCTION...6-1 6-2. DELUXE CARRYING CASE (C90)...6-I 6-3. TEMPERATURE Probe (80T-150C and 80T-150F) . 6-1 6-4. CURRENT TRANSFORMER (801-600) ...6-4 6-5. HIGH VOLTAGE Probe 80K-6 6-4 6-6. HIGH VOLTAGE Probe 80K-40 6-4 6-7. HIGH FREQUENCY Probe (83RF) ...6-5 6-8. HIGH FREQUENCY Probe (85RF) ...6-5 6-9. BATTERY ELIMINATOR (A81) ...6-6 6-10. CURRENT SHUNT (80J-10) ...6-6 6-11. AC/DC CURRENT Probe Y8100 6-7 6-12. AC CURRENT TRANSFORMER (Y8101)...6-8 6-13. SAFETY DESIGNED TEST LEAD SET (Y8132)...6-8 6-14. DELUXE TEST LEAD SET (Y8134) ...6-8 6-15. SLIM FLEX TEST LEAD SET (Y8140) ...6-8 6-16. CABLES AND ADAPTERS ...6-9 7 SCHEMATIC DIAGRAMS ...7-1

show more