Hewlett Packard - 333A - Analyzer
Manufacturer:

Image 1 of 1
If you have any other photos or manuals for the
Hewlett Packard 333A
you can
upload the files here.
Equipment:
333A
Date:
1967
Category:
Group:
Sub Group:
Information
The Hewlett-Packard Models 333A and 334A Distortion
Analyzers are solid state instruments for measuring
distortion and ac voltages. The Models 333A and 334A include
two control loops that automatically tune both legs of a
bridge circuit which rejects the fundamental when the
rejection circuit is initially set within the range of the
loops. A high impedance detector which operates from 500 Kc
to greater than 65 Mc provides the capability” of monitoring
the distortion of the amplitude modulation on an rf carrier.
1-3. Distortion levels of O. 1% to 1OO% full scale are
measured in seven ranges for any fundamental frequency of 5
cps to 600 Kc. Harmonics are indicated up to 3Mc. The high
sensitivity of these instruments requires only O. 3 v rms
for the 100% set level reference. The distortion
characteristics can be monitored at the OUTPUT connectors
with an oscilloscope, a true rms voltmeter, or a wave
analyzer. The instruments are capable of an isolation
voltage of 400 volts above chassis ground.
1-4. The voltmeter can be used separately for general
purpose voltage and gain measurements. It has a frequency
range of 5 cps to 3 Mc (20 cps to 500 Kc for 300 pv range)
and a voltage range of 300 pv to 300 v rms full scale.
1-5. The AM detector included in the Model 334A is a
broadband dc restoring peak detector consisting of a
semiconductor diode and filter circuit. AM distortion levels
as low as O. 3% can be measured on a 3 v to 8 v rms carrier
modulated 30% in the standard broadcast
band, and lower than 1% distortion can be measured at the
same level of the carrier up to 65 Mc.
3 Manuals
Service and user manual
Manual type:
Service and user manual
Pages:
53
Size:
1.3 MB
Language:
english
Revision:
Manual-ID:
Date:
Quality:
Scanned document, all readable.
Upload date:
May 31, 2015
MD5:
a7196535-7f18-4688-c02a-2e6c75db4cb1
Downloads:
947
Information
This manual includes installation and operation instructions
and covers operator’s, organizational, direct support (DS),
general support (GS), and depot maintenance. It describes
Hewlett-Packard (Federal support Code 80537) Distortion
Analyzer Models 333A and 334A (fig. l-l). A basic issue
items list for this equipment is not included as part of
this manual.
Service and user manual
Manual type:
Service and user manual
Pages:
86
Size:
4.4 MB
Language:
english
Revision:
Manual-ID:
00333-90005
Date:
October 1971
Quality:
Scanned document, reading partly badly, partly not readable.
Upload date:
Dec. 30, 2017
MD5:
a0771943-63fe-aef6-4ea6-11d11ad41d3b
Downloads:
851
Datasheet
Manual type:
Datasheet
Pages:
2
Size:
262.8 KB
Language:
english
Revision:
Manual-ID:
Date:
Quality:
Scanned document, reading partly badly, partly not readable.
Upload date:
May 31, 2020
MD5:
a0b79211-593a-e364-b71a-f83403a18a94
Downloads:
728