Information
The HP 54201A and HP 54201D Digitizing Oscilloscope are dedicated, two-channel, simultaneous, waveform acquiring digital storage Oscilloscope with full HP-IB programmability,
digitized waveform data output, and resident parametric waveform measurements.
HP 54201 A/D - General Information
The HP 54201 A/D is a general purpose digitizing Oscilloscope with 300 MHz repetitive bandwidth
and a single-shot digital storage bandwidth of 50 MHz (200 rneqasamples/second) with infinite
store time and waveform data output. It also provides parametric information about the analog
characteristics of waveforms.
The HP 54201 D has all the features of the HP 54201A with the addition of parallel and serial logic
trigger qualification capabilities. The HP 54201 D includes 3 pods, each containing 8 bit + 1 parity
bit + clock organization.
The key features of the HP 54201 A/D Digitizing Oscilloscope are:
• 300 MHz repetitive bandwidth with ±200 ps time-interval accuracy.
• 200 rneqasarnples/second sample rate, 50 MHz single-shot bandwidth using post capture
data interpolation.
• Capture two channels simultaneously.
• Holdott-by-events to trigger acquisition after a specified number of events.
• Pre-trigger viewing.
• All front panel controllable parameters can be programmed via HP-IB.
• Continuously updated automatic waveform parameter measurements with
user-defined thresholds.
• Waveform math: Ch1 +Ch2 and Ch1-Ch2.
• Set up aids such as automatic waveform scaling, ECl/TTl preset levels, and save/recall of
front-panel setups.
• One button hardcopy to HP-IB printers and plotters.
• Digital logic trigger qualification (HP 54201 D only).
2 Manuals
User manual
Manual type:
User manual
Pages:
250
Size:
6.1 MB
Language:
english
Revision:
Manual-ID:
54201-90901
Date:
January 1986
Quality:
Scanned document, all readable.
Upload date:
June 7, 2020
MD5:
6c534596-3b14-ff22-983c-af6d6ebebe9e
Downloads:
2302
Information
Operating and Programming Manual
This manual contains information concerning the operation and programming of the HP 54201A and HP 54201 D Digitizing Oscilloscope When information concerns both models the system will be referred to as the HP 54201A D.
MANUAL ORGANIZATION
Section 1, General Information.
This section contains a description of this manual and the instrument.
Section 2, Getting Started.
This section explains how to prepare the HP 54201A D for use.
Section 3, Front Panel Controls and Menus. This section familiarizes the user with the front panel
controls and menu structures of the HP 54201A D.
Section 4, Front Panel Exercises. This section provides step-by-step exercises to familiarize the
user with making measurements from the front panel of the HP 54201A D.
Section 5, State Triggering with the HP 54201D This section discusses the operation of the state
triggering feature of the HP 54201 D.
Section 6, Peripherals. This section provides information for making hardcopy prints of the HP
54201A/D display using a plotter or graphic printer.
Section 7, Remote Control Operation. This section discusses the remote operation of the HP
54201A/D over HP-IB, including compatibility, remote/local modes, local lockout, learn and
calibration strings, and notation and definitions. This section should be reviewed before writing
programs for this instrument.
Section 8, Programming the HP 54201A D. This section provides programming instructions for the instrument, including the instruction set, syntax diagrams, and other detail programming reference information.
Service manual
Manual type:
Service manual
Pages:
173
Size:
3.9 MB
Language:
english
Revision:
Manual-ID:
54201-90902
Date:
January 1986
Quality:
Scanned document, all readable.
Upload date:
June 7, 2020
MD5:
fba8240c-d5df-c877-186f-9625beda6bc3
Downloads:
839
Information
This manual applies directly to instruments with serial number prefixes:
HP 54201 A; 2602A
Hp 54201 D; 2602A
This manual contains technical information concerning the installation, performance testing,
adjustments, and servicing of the HP 54201A and HP 54201 D Digitizing Oscilloscope When
information concerns both models the system will be referred to as the HP 54201A D.
MANUAL ORGANIZATION
Section 1, General Information. This section contains a description of this manual and the
Instrument.
This section also gives the specifications, general characteristics, operating
characteristics and recommended test equipment for the HP 54201A D.
Section 2, Installation.
This section explains how to prepare the HP 54201 A/D for use.
Section 3, Performance Tests. This section describes both the self test capabilities of the HP
54201 A/D as well as the procedures for the full Performance Test.
Section 4, Adjustments. The HP 54201 A/D requires several adjustments to restore specified
performance after some major repairs have been made. This section provides the necessary
adjustment procedures.
Section 5, Replaceable Parts. This section contains ordering information and a list of all
replaceable parts in the HP 54201A D system.
Section 6, Service.
This section contains disassembly and assembly procedures and
documentation and procedures for isolation and replacement of faulty circuit boards.
Service Group 6A Power Supply This section contains block diagrams and component level
theory, troubleshooting and schematic information necessary to service the HP 54201 A/D power
supply.
Appendix A, Self Test Documentation. This section contains an overview of how the HP 54201A D
self tests work and what portions of the HP 54201 A/D circuitry they check.