The GSP-827 is designed with the features as follows.
Synthesized-based design covering the frequency from 9kHz
to 2.7GHz.
Low noise design: -140dBm/Hz noise floor.
4.5kg light weight and compact size.
100 traces and setup memories.
ACPR, OCBW, CHBW of power measurement.
11 ranges of external reference clock (64k~19.2M).
10 Markers with Peak, Peak Track, ΔMarker, Marker to Center
functions.
External and Video Level Trigger with single and continuous
modes.
Limit Line and Pass/Fail functions for quickly
qualification test.
Spilt Windows extend the measurement flexibility.
Trace functions including Peak Hold, Average and Freeze.
Optional Tracking Generator provides frequency response
measurement in one sweep.
Optional filters and Quasi- Peak detection provide EMI test.
GPIB and RS232 interface for ATE applications.
AC/DC dual modes power supply and Battery Operations.
The fully synthesized-based and low noise designs offer the
high RF performance in
measurement. The plentiful measurement functions like 10
markers, traces, power
measurement, limit line, dual display and trigger make
measurement more easily and quickly.
The 100 memories, real time calendar and battery operation
realize the true portability. 11
ranges of external reference clock offer the synchronization
capability to many telecom
standards. The optional Tracking Generator offers the
frequency response test with the same
frequency band. The GPIB and RS232 interfaces allow the
connection between the unit and
PC. Users can develop their own applications software. DC
12V power supply allows user to
carry this unit to drive around for frequency monitoring.
Chargeable battery pack can support
the operation without power cord for 4 hours. With the
carrying case, this unit is easy to carry
and operate in the filed service. 9k and 120k EMI filter and
quasi-peak detector can perform
the EMC test. AM/FM Demodulation provides the demodulated
outputs through both
headphone and speaker. Kit sets of connector adaptor offers
the convenience under different
measurement conditions.
This unit offers the right combination of highly RF
performance, plentiful function, easily
operated user interface and complete options to facilitate
measurement in a wide range of
application in laboratory as well as in field service usage.
This is another example of our
dedication to engineering excellence.
1 Manual
User manual
Manual type:
User manual
Pages:
98
Size:
2.7 MB
Language:
english
Revision:
Manual-ID:
82SP-82700MA
Date:
Quality:
Electronic document, no scan, very well readable.
Upload date:
May 14, 2017
MD5:
5a5f1ff9-e176-9446-7995-5603b11093d9
Downloads:
381